SNC 5100

Figure 6: Detail of Event Log Listing From Service Port

Step 4. Check the listed Event Codes against the Event Code column of Table 7 on page 35.

See Figure 6 to interpret the log listing.

Step 5. Read across Table 7 to the Action column to see the associated Action number.

Step 6. Find the Action number in the Action column of Table 8 on page 41.

Step 7. Complete the indicated MAP or action.

Step 8. To see additional log messages, follow the procedure “Event Log Dump” on page 189.

Step 9. If there are no abnormal events, go to “Perform Health Check” on page 46.