The example below shows the display for a test on SCSI channels 1 and 2.

diagmode > scsiChannelTest (3,4)

 

SCSI-3 ->

SCSI-4 [##########] 10 iterations PASSED

SCSI-4 ->

SCSI-3 [##########] 10 iterations PASSED

value = 0

= 0x0

 

 

diagmode > scsiChannelTest (1,2)

 

SCSI-1

->

SCSI-2

[##########] 10

iterations PASSED

SCSI-2

->

SCSI-1

[##########] 10

iterations PASSED

value = 0

= 0x0

 

 

The following output is an example of a SCSI port test that was not successful. If your test was not succesful, return to the MAP that sent you here.

Unsuccessful SCSI Test (cable not plugged in):

diagmode > scsiChannelTest (1,2) SCSI Initiator Error(s) - STO iUnk SCSI Initiator Error(s) - STO iUnk

SCSI-1 -> SCSI-2 [SCSI Initiator Error(s) - STO iUnk ERROR, i = 1 ] 1 iterations FAILURE

SCSI-2 -> SCSI-1 [SCSI Initiator Error(s) - STO iUnk ERROR, i = 1 ] 1 iterations FAILURE

value = -1 = 0xffffffff = pNullDmaDesc + 0xfe4ea9f7

showBox

The showBox command displays the components present in the SNC 5100 using characters to form a picture of the unit, as viewed from the rear.

194 Diagnostic Commands

6-00020-02