SNC 5100

Exit this MAP.

If the front-panel FC Connection Status LED is on, proceed to Step 3.

Step 3. If the SNC 5100’s command prompt on the service terminal is not

diagmode >, place the SNC 5100 in diagnostic mode.

For more information, see “Entering Diagnostic Mode” on page 187.

Step 4. Substituting the Fibre Channel slot number for x, enter the fcSlotTest x command.

For more information, see "fcSlotTest [x]" command on page 192.

Step 5. If the test failed, replace the SNC 5100.

Go to “Before Removing or Replacing the Unit” on page 82.

Continue through “Replacing the SNC 5100” on page 84.

Exit this MAP.

If the test passed, the Fibre Channel port is good.

Step 6. Remove the loop back plug.

Go to "Testing Fibre Channel Optical Cable".

Testing Fibre Channel Optical Cable

Caution

If the Fibre Channel cable is extremely long it may be more practical to replace the Fibre Channel device first; then if the problem is not resolved, replace the cable.

Step 1. If the cables are already removed, reattach them.

Attach matching cable ends (red-to-red or ‘A’-to-’A’ and so on) to both slots of the Fibre Channel port.

Step 2. Substituting the Fibre Channel slot number for x, from the service terminal enter the fcSlotTest x command.

64 Fibre Channel MAP

6-00020-02

Page 72
Image 72
ADIC Scalar 1000, SNC 5100 manual Testing Fibre Channel Optical Cable