route delete,destination,gateway

The route deletecommand removes a route to the destination through the gateway.

SN60023 > route "delete","200.0.0","bruno"

SN60023 >

route list

The route listcommand lists the existing routes.

SN60023 > route "list" Destination SNC 5100

-------------------- --------------------

socrates bruno Destination SNC 5100

-------------------- --------------------

200.0.0bruno

value = 0 = 0x0 SN60023 >

rtcDateSet[year],[month],[dayofmonth],[dayofweek],

[hour],[minute],[second]

The rtcDateSet command allows you to set the date and time manually.

You must use a 24-hour clock.

All parameters are digits.

The year can be either two or four digits.

Single digit months or hours should not be filled out with leading zeroes.

A digit from 1-7 needs to be entered for the [dayofweek] parameter, but it doesn’t matter what you enter, since the command will automatically correct it if it is wrong.

To display the new time and date data after entering the rtcDateSet command, enter the date command.

To set the RTC to 9:35 A.M. on Friday, January 26, 2001, enter the following