SNC 5100

Table 7: Event Codes and Actions

Event

Viewing

Default

 

Action2

Trap

Description

Code

Level1

Threshold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

102

1

 

Temperature change detected since

4, 0

 

 

 

the last report (event message

 

 

 

 

indicates the change to High, Very

 

 

 

 

High, Reduced to High, or OK)

 

 

 

 

 

 

106

1

1

Fibre Channel interface failed Health

2

 

 

 

Check

 

 

 

 

 

 

107

1

1

SCSI interface failed Health Check

1

 

 

 

 

 

109

1

1

Target device failed Health Check

1

 

 

 

 

 

110

1

1

Fibre Channel link status changed

0, 2

 

 

 

 

 

111

1

1

Fibre Channel transfer failures

0

 

 

 

detected since the last report

 

 

 

 

Caution: error recovery may have

 

 

 

 

succeeded

 

 

 

 

 

 

112

1

1

Blower/Fan is running in Warning or

4

 

 

 

Alarm Range

 

 

 

 

 

 

113

1

1

Power is running in Warning or

5

 

 

 

Alarm Range

 

 

 

 

 

 

114

1

1

Temperature is running in Warning or

4

 

 

 

Alarm Range

 

 

 

 

 

 

115

1

1

Network is running at 10 Mb/sec

7

 

 

 

 

 

 

 

 

Heartbeat Event Descriptions

 

 

 

 

Caution: These event codes are not

 

 

 

 

logged in the Event Log. Notification

 

 

 

 

of these events occurs from the ADIC

 

 

 

 

Management Console. For more

 

 

 

 

information on Heartbeat, see the

 

 

 

 

ADIC Management Console User

 

 

 

 

Guide.

 

 

 

 

 

 

2005

N.A.

N.A.

The Server could not verify the

7,3

 

 

 

connection to the SNC 5100

 

 

 

 

 

 

2016

N.A.

N.A.

The Client could not communicate

7,9

 

 

 

with the Server

 

 

 

 

 

 

2026,7

N.A.

N.A.

The Server could not communicate

7,9

 

 

 

with the Client

 

 

 

 

 

 

40 Event Codes and Actions

6-00020-02

Page 48
Image 48
ADIC Scalar 1000, SNC 5100 manual Heartbeat Event Descriptions