SNC 5100

Input Power:

+5 Volts

(V):

 

Nominal:

4.83

to 5.20

 

Warning:

4.75

<= N <

4.83 or 5.20 < N <= 5.25

Alarm:

N < 4.75 or

N > 5.25

Input Power:

+12

Volts (V):

 

Nominal:

11.00 to 12.93

Warning:

10.75 <= N < 11.00 or 12.93 < N <= 13.18

Alarm:

N < 10.75 or N > 13.18

Local Power:

+2.5 Volts (V):

 

Nominal:

2.42

to 2.58

 

Warning:

2.36

<= N <

2.42 or 2.58 < N <= 2.62

Alarm:

N < 2.36 or

N > 2.62

Local Power:

+3.3 Volts (V):

 

Nominal:

3.20

to 3.39

 

Warning:

3.13

<= N <

3.20 or 3.39 < N <= 3.46

Alarm:

N < 3.13 or

N > 3.46

Local Power:

+3.3 Volts Aux (V):

Nominal:

3.20

to 3.39

 

Warning:

3.13

<= N <

3.20 or 3.39 < N <= 3.46

Alarm:

N < 3.13 or

N > 3.46

Fan :

 

 

 

 

Nominal: 1;

Alarm: 0

 

 

value = 1 = 0x1 SN600012 >

ethAddrGet

The ethAddrGet command displays the IP address of the SNC 5100, specified as 4 decimal numbers separated by periods

SN60023 > ethAddrGet

IP Address set to 192.168.1.176 value = 0 = 0x0