SNC 5100
150 Commands 6-00020-02
inetstatShow - Display all Internet protocol sockets
ipstatShow - Display statistics for IP
macShow - Display Media Access Control Address
mbufShow - Display mbuf statistics
route "<func>","destination","gateway"
func - "add" - add route to route table
- "delete" - delete route from route table
- "list" - list route table
tcpstatShow - Display statistics for TCP
udpstatShow - Display statistics for UDP
See Users Guide for more information
value=0=0x0
SN60023 >
normalBoot
Certain commands and tests are only available in diagnostic mode.
Switching to diagnostic mode saves all configuration parameters so that they
are restored before returning to normal operation. Use the normalBoot
command to restore the SNC 5100 to normal operating conditions.
This command is used only to transition an SNC 5100 from the special
diagnostic mode to normal operations. It restores the bootline that was copied
by diagBoot. The new persistent device map is erased, and the original map
file is renamed config/device.map restoring it for use when the SNC
5100 reboots. The normalBoot command will then reboot the unit.
rdate timeserver
The rdate timeserver command sets t he system date and time to be read
from a remote system. The "setTimeHost" command on page 164 must
already have been entered before the rdate timeserver command is
issued. To see data from the new setting, use the date command. To set the
date and time to be read from a remote system named Cronos, enter the
following command:.
SN60023 > rdate Cronos
value=0=0x0
SN60023 >