SNC 5100

inetstatShow

- Display all Internet

protocol sockets

ipstatShow

-

Display statistics

for

IP

macShow

- Display Media

Access

Control Address

mbufShow

- Display mbuf

statistics

 

route "<func>","destination","gateway" func - "add" - add route to route table

-"delete" - delete route from route table

-"list" - list route table

tcpstatShow - Display statistics for TCP udpstatShow - Display statistics for UDP

See User’s Guide for more information

value = 0 = 0x0 SN60023 >

normalBoot

Certain commands and tests are only available in diagnostic mode. Switching to diagnostic mode saves all configuration parameters so that they are restored before returning to normal operation. Use the normalBoot command to restore the SNC 5100 to normal operating conditions.

This command is used only to transition an SNC 5100 from the special diagnostic mode to normal operations. It restores the bootline that was copied by diagBoot. The new persistent device map is erased, and the original map file is renamed config/device.map restoring it for use when the SNC 5100 reboots. The normalBoot command will then reboot the unit.

rdate timeserver

The rdate timeservercommand sets the system date and time to be read from a remote system. The "setTimeHost" command on page 164 must already have been entered before the rdate timeservercommand is issued. To see data from the new setting, use the date command. To set the date and time to be read from a remote system named “Cronos,” enter the following command:.

SN60023 > rdate “Cronos” value = 0 = 0x0 SN60023 >

150 Commands

6-00020-02

Page 158
Image 158
ADIC Scalar 1000, SNC 5100 manual NormalBoot, Rdate timeserver