User Guide
Copyright Notice
Copyright Notice Europe
Introduction
Install the SNC
Maintenance Action Plans
Removal and Replacement Procedures
Diagnostic Command Reference
Connecting to the Service Port
Service Port Command Reference
Post Error Codes
Warranty and Eula
Startup Message Reference
Glossary
Welcome
Safety Notices
Safety Inspection
Remove AC Power
Safety Label Check
Safety Label
External Machine Check
Fusing Requirements
Laser Safety
Lithium Battery
Environmental Notices and Statements
General Restrictions
Usage Restrictions
Regulatory Notices
Electronic Emission Statements
Industry Canada Compliance Statement
European Community Compliance Statement
SNC
CE Notice
Documentation
Configuration Overview
Overview
Interface Protocol Awareness
Configuration Support
Address Mapping
Hardware Product Description and Features
Fibre Channel Interfaces
Fibre Channel Connections
Gbic speed Cable Type Distance
Ultra2 Scsi I/O Interfaces
Ethernet
Scsi Command Support
Service Port
LED Indicators
LEDs
Supported Platforms
Scsi
Operating Environment
Operating Specifications
Supported Devices
Power Consumption
Power Requirements
SNC Operating Specifications 00020-02
Step Actions Comments and References
Pre-installation Procedure
Pre-Installation Checklist
Installation Procedure
Installation Checklist
Installation Checklist
See the setHost port,OS
Host Utility Software
Host Utility Software
Post-Installation
Other Installation Issues
Attaching Scsi Devices
Maximum Number of LUNs
Transfer Rates Ultra, Fast, and Asynchronous
Wide and Narrow Scsi Buses
Table of Scsi Terminology and Limitations
Scsi Trade Association Terminology
Max Bus Endorsed Terminology Max. Bus Speed Lengths
MB/Sec Devices
Problems on the Scsi Bus
Scsi Bus Termination
Bent pins in a Scsi connector
Missing terminator at the end of a Scsi bus
Excessive termination
Multiple devices at the same ID
Host Bus Adapter Setup
Fuses
Inadequate cables
Mixed cable types
Power-Up and Boot Sequence Guidelines
Installing the SAN Explorer
Installing the Host Registration Service
SNC
SNC Other Installation Issues 00020-02
Maintenance Action Plans Troubleshooting Table
Component Subsystem Go To
Review all visual observations and Event Codes against on
Event Codes and Actions
Check Event Log
Event Viewing Default Action2
Event Codes and Actions
Description
Code Level1 Threshold
Event Viewing Default Action
Code Level Threshold
Description Code Level1 Threshold
LIP
Event Codes and Actions
Health Check Event Descriptions
Heartbeat Event Descriptions
Action Number
Action Reference Table
Action Reference Table
Event Code or Obvious Symptom
Start MAP
Event Viewing Levels
Event Viewing Levels
Visually Inspect LEDs
Check for Problems on Attached Devices
Check SNC 5100 Product Versions
Check Host Versions
Adic Management Console version
Firmware version
Hardware version
Perform Health Check
Stop all I/O Remove the Ethernet cable if installed
Quick Component Check
Database Full MAP
Check the Host Event Log
Device Access MAP
Check Fibre Channel Port Status
Check Scsi Channel Devices
Get Scsi Information for the SNC
Check Channel Zoning Settings
Scsi Channel MAP
Check Attached Scsi Devices from the Service Port
Compare Listed versus Physical Devices
Compare Listed versus Supported Devices
Check Scsi Bus Termination
Check for Multiple Scsi IDs
Type
Improper Device Type
Examine Scsi Cables
Examine Scsi Connectors
Scsi Health Check
Scsi Loop Back Test
Testing Scsi Cables
Isolating Scsi devices
Restore Scsi Setup
Fibre Channel MAP
Verify Fibre Channel Connections
Test Gbic
Examine Cables
Fibre Channel Loop Back Test
Testing Fibre Channel Optical Cable
Replace Fibre Channel Cable
Replace Fibre Channel Device
Observe Operational LED Behavior
Temperature MAP
MAP for the SNC
Notification of Problems in Temperature Subsystem
Temperature Warnings or Alarms Received
Power MAP
Fan Speed is in Warning or Alarm Range
Ethernet MAP
Ethernet Port on Faceplate
SNC
Example SN60023 ifShow
SNC
Display of failed Ping test
From the service terminal, enter the diagBoot command
From the service port, enter the elTest command
Step
Verify that the diagmode prompt is displayed
Service Port MAP
If both addresses are the same, go to step
Check Connection with Boot Messages
Check the RS-232 Cable
Perform these steps if SFM devices are unavailable
Virtual Private SAN Scalar Firewall Manager Settings MAP
Check Scalar Firewall Manager Access Settings
Verify Host Access to Devices
SNC
Page
Removal and Replacement Procedures
Handling Electrostatic Discharge-Sensitive Parts
Removing and Replacing the Gbic
Before Removing or Replacing the Unit
Removing the Gbic
Replacing the Gbic
Removing and Replacing the Unit
Removing the SNC
Final Test Preparation
Final Diagnostic Tests
Replacing the SNC
Fibre Channel Tests
Test Fibre Channel Port
Test Scsi Port 3
Ethernet Test
Test Scsi Port 1
Network Setup for the SNC
For more information, see Network Setup for the SNC
, Pre-Installation Checklist, on
Enter the hostNameSet command to set the Host name
For more information, see the hostNameSet command on
Ethernet Port
Foster ethAddrSet 10.0.0.2
Checklist
Updating the SNC
Post-Repair Checklist
Post-Repair Checklist
Start the Adic
FcShowDevs
SNC Post-Repair Checklist 00020-02
Service Port Connections
DB-9 RS-232 Connector Pin Assignments
Connecting the Service Terminal
Hardware Required
Lists the null modem cable connections
Null Modem Cable Connections
Initial Setup of HyperTerminal
Verifying the Connection
Updating Firmware and Configurations
Updating SNC 5100 Firmware
Saving a Configuration File
Loading a Configuration File
Status Description Code
Zmodem Status Code Table
Zmodem Status Codes
Setting the Time and Date
Setting the Real Time Clock
For more information, see the tzSet timezone command on
Adding a Host System Running Timeserver
For more information, see the setTimeHost command on
Disabling the Timeserver Host
For more information, see the rtcSetCurrent command on
Synchronizing the Real Time Clock with a Timeserver
Commands
Commands Listed Alphabetically byFunction
Command or Command Description Group Command and Control
Managing the SNC
Command or Command Description Group
Diagnostics
Environmental Sensors
Ethernet Network
Event Logging
Fibre Channel
Help
Flash File System
Health Check
Product Data
Scalar Firewall Manager
Scsi
Startup
Parameter Value
ArptabShow
ClearReservationdevId
CleHelp
CleShow LUN
CleShowAll
CsClearLogFile
DiagBoot
DiagHelp command displays a list of the diagnostic commands
DateSetFromRTC
DiagHelp
DisableCC option number
Option
Channel Name Description
EnableCC
EnvMonShow
EnvMonRangeShow
EthAddrGet
Parameter Value Meaning
EthAddrSet
FcConnTypeGet port
FcConnTypeSet port,connection
FcFibreSpeedGet port
FcFibreSpeedSet port,speed
FcGbicShow port
GBIC. Specifying the port number is optional
Finisar Corp
Value Port Mode
FcPortModeGet port
FcPortModeSet port,mode
FcRestart port
FcShow level
Level Meaning
Ctlr Id
FcShowDevs
Ext. Fifo
FcShowNames
FcTxDisable port
FcTxEnable port
GateAddrGet
GateAddrSet
Help
Help command displays a list of the shell commands
Terminal
Commands 133 00020-02
HlthChkIntervalSet
HlthChkHelp
HlthChkIntervalGet
HlthChkLevelGet
HlthChkLevelSet
HlthChkNow
Host add,hostname,ipAddress
Host delete,hostname
Following is an example of host file contents
Where
Host list
HostNameSet
HostShow
HostTypeShow
IcmpstatShow
IfShow
InetstatShow
InitializeBox
LoggerDump number
IpstatShow
LicenseShow
LoggerDumpCurrent level
File are displayed starting with the most recent events
SN600393
Ls or ll
MacShow
Ethernet interface
MapCompressDatabase
MapHelp
MapRebuildDatabase
MapShowDatabase
MapShowDevs
SNA
MbufShow
MapWinnowDatabase
MapWinnowDatabaseLun dev ID
Administrator
NetHelp
NormalBoot
Rdate timeserver
Reboot
Reset
ReserveShow level
ReserveShow Viewing Levels
On original equipment, the RID tag will be blank
RestartScsi channel
Ridtag value
Route
Route add,destination,gateway
Route list
Route list command lists the existing routes
Route delete,destination,gateway
String
RtcSetCurrent
ScsiAltIdGet channel
ScsiAltIdSet channel,id
ScsiHostChanGet channel
ScsiHostChanSet channel,mode
ScsiRescan channel
ScsiHostIdGet channel
ScsiHostIdSet channel,id
ScsiResetDisableGet channel
ScsiResetDisableSet channel,mode
ScsiShow
LUN
SetFcFrameSize channel,size
ScsiTermGet channel
ScsiTermSet channel,termination
SetFcHardId channel,id
SetHost port,OS
SetNettime value
Value Meaning
SetTimeHost
SfmAccessApply
SetSnaCCLun newLUN
SfmAccessClear disable code
SfmAccessSet hostindex,Starting LUN,Ending LUN,Access
Access Value
SfmActiveSet
SfmFeatureEnable license key string
Following command example shows SFM information for host Id
If SFM is already active, the following is displayed
SfmConnectionSet hostindex,host connection string
SfmNameSet hostindex,name string
SfmInactiveSet
If SFM is already inactive, the following is displayed
SfmShow hostIndex
Hostindex Meaning
ShellLock
SfmSparseAccessSethostindex,LUN string,Access
SfmTypeSet hostIndex,OS type string
ShowBox
ShowVersions
SncFeatureEnable licensekeystring
SnmpCommunitiesShow
SnmpHelp command displays a list of the snmp commands
SnmpHelp
SnmpReadCommunityAdd string ,view
SnmpReadCommunityRemove string
SnmpTrapCommunitySet string,view
SnmpWriteCommunityAdd string,view
SnmpWriteCommunityRemove string
SysConfigShow
SysNodeNameModeSet Mode
SysVpdShow or sysVpdShowAll
Mode Definition
SysNodeNameModeShow
OEM Adic
Data for the Fibre Channel Gbic
IBM
Gbic
NV RAM CPU
Sz filename
Targets
TcpstatShow
TrapDestAdd ipAddress
TrapDestRemove ipAddress
UdpstatShow
TrapDestShow
TzSet timezone
UserAdd username,password
UserDelete username,password
Uptime
User
UserHelp command displays a list of the user commands
UserList
UserHelp
Version
SNC
Boot Modes
Entering Diagnostic Mode
Special Procedures
Restoring Normal Mode
Health Check
Manual Health Check
Retrieving the Code 43 Dump File
Event Log Dump
SNC
Boot Mode Commands
Diagnostic Commands
ElTest
FcSlotTest
ScsiChannelTest x,y
Unsuccessful Fibre Test
Unsuccessful Scsi Test cable not plugged
ShowBox also lists the cabling requirements for each slot
SupportDump
EnvMonShow dmva reserveShow
Post Boot Behavior
ROM Init
Simple Access Test
Initial Post
Pattern Test
Bitwalk Test
Memory Size
Address Test
Identify and Execute bootrom
Secondary Post
Post Service Menu
Start of Bootrom
Cold boot from Alternate bootrom
Cold Boot from primary bootrom
Button may be depressed any time during the memory tests
After completing the memory tests Post will display
Full Version information
Error Displays
Receive new boot image from serial port
SNC Post Service Menu 00020-02
Bootrom Messages
See the sample code below
LIC Initialization Messages
Final Startup Messages
SNC Bootrom Messages 00020-02
Dynamic Random Access Memory
Maintenance Action Plan
Basic Input/Output System
Differential Ended
Power-On Self test
Replacement Identification
Synchronous Dynamic Random Access Memory
SAN Replication Services
Warranty and Eula
Adic Limited Product Warranty
Adic Limited Product Warranty 00020-02
Adic End User License Agreement
Adic End User License Agreement 00020-02
Adic End User License Agreement 215 00020-02
SNC
Bootrom 110, 171
Index
Post
MAP
SNC 220 00020-02