SNC 5100

Step 3. Wait for the SNC 5100 to finish booting.

Step 4. If the SNC 5100 is in diagnostic mode (command prompt = diagmode >), then restore normal operation.

For more information, see “Restoring Normal Mode” on page 188.

Step 5. Perform a health check.

For more information, see “Perform Health Check” on page 46.

Step 6. Review the host event log.

For more information, see “Check the Host Event Log” on page 47.

If all attached SCSI devices and cables are determined to be good, yet SCSI errors persist, replace the SNC 5100.

Go to “Before Removing or Replacing the Unit” on page 82.

Proceed through “Replacing the SNC 5100” on page 84.

Exit this MAP.

Fibre Channel MAP

Perform these steps if:

The Fibre Channel interface reports a reset or system error

The Fibre Channel interface reports an error processing a request or response

The Fibre Channel interface reports an excess of 10 LIPs in a 10-minute interval

Other Fibre Channel errors reported

FC connection LED is off

Verify Fibre Channel Connections

Step 1. Connect the service terminal to the Service Port.

For more information, see “Connecting to the Service Port” on page 95.

Fibre Channel MAP

61

6-00020-02

Page 69
Image 69
ADIC SNC 5100, Scalar 1000 manual Fibre Channel MAP, Verify Fibre Channel Connections