SNC 5100

Cables should have a duplex SC connector on the GBIC end and a connector appropriate to the HBA in use on the host end.

Fibre Channel interfaces support the following Public and Private Loop modes:

Target

Initiator

Target and Initiator

The maximum number of initiators connected via Fibre Channel is 64 per Fibre Channel port.

Fibre Channel Interfaces also support the following connection options:

Loop

Point-to-Point

Loop Preferred

The Fibre Channel controller is compliant with the following standards and specifications:

Fibre Channel Arbitrated Loop (FC-AL-2) working draft, rev 6.4, August 28, 1998

Fibre Channel Fabric Loop Attachment (FC-FLA) working draft, rev 2.7, August 12, 1997

Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) working draft, rev 2.1, September 22, 1997

Fibre Channel -- Tape and Tape Medium Changers (FC-Tape), Rev 1.17, Technical Report, T11/99-069v4

Fibre Channel protocol SCSI (FCP-SCSI)

Ultra2 SCSI I/O Interfaces

Four Low Voltage Differential (LVD) Ultra2 SCSI channels with internal termination.

SCSI channels have automatic speed and width negotiation capability for wide or narrow bus widths and Standard, Fast, Ultra or Ultra2 speeds.

SCSI channel support for up to 15 SCSI target IDs and up to 32 LUNs per ID (subject to an overall total of 2048 devices). The SNC 5100 uses one

12 Hardware Product Description and Features

6-00020-02