Robertson AP45 Autopilot | Page |
Installation |
|
The output from the navigational receiver is connected to AP45 J3 pin 9 and 10 (Ref. Fig.
| Fig. |
| AP45/Navigation receiver - Wiring |
Watch alarm | AP45 is originally designed for connection to an external watch alarm of type WA9 |
| which is no longer available. WA9 was connected to J1 as per Fig. |
| However, it is still possible to enable the built in watch alarm in AP45 by |
| temporarily connect pin 2 of J1 (Watch al. sense) to pin 13 (Gnd). The watch alarm |
| function can be permanently disabled again by following the procedure described |
| in section “Fault warnings” page |
|
Fig.
WA9 Circuit/Wiring diagram
Note!
If pin 2 of J1 has a fixed connection to pin 13 (Gnd) it is not possible to disable the watch alarm.
Simrad Robertson AS
Egersund - Norway