Page 5-2

Robertson AP45 Autopilot

 

Installation

Connector assemble The cable conductors are connected to the connector block according to separate connection diagrams. The following tools are required to crimp the connector pins and sockets to the individual cable conductors.

Crimping tool :

Amp 90277-1

Extraction tool: Amp 725840

Note!

Do not use other tools than those specified!

For protection against electro magnetic interference, all control unit connectors must be fitted with the supplied metal shell and cover.

Strip about 1 cm (0.4") of the cable insulation and pull the screen backwards to cover the insulation. Screw the connector block onto the actual control unit socket. Screw the shell onto the connector block. Fix the cable screen to the shell by a wire strap and tighten well to make sure the screen has good contact. Apply a thin layer of pure Vaseline on the shell threads. Screw the cover onto the shell until it makes good contact with the control unit cabinet.

The control unit has a ground terminal and must have a proper ground connection to the hull. The grounding wire should be as short as possible and at least 10 mm wide.

Fig. 5-3

Control unit - connector mounting

Simrad Robertson AS

Egersund - Norway