Image 78

Page 5-28

Robertson AP45 Autopilot

 

Installation

FU91 Steering Lever Mounting

Fig. 5-31

FU91 Mounting

For bulkhead mounting, use the 8 bushings enclosed with the unit. These are placed two and two against each other and the screws are put through them. Direct contact between FU91 and a steel bulkhead is then avoided and corrosion is prevented. The cover plate can be turned 360 degrees for the most convenient position of cable outlet. For panel mounting use the two mounting brackets enclosed with the unit.

Electrical connection

There is two alternatives of connecting FU91 to AP45; without mode switching or with mode switching (similar to S9)

Fig. 5-32

FU91 without mode switching

See page 2-14for operation.