Robertson AP45 Autopilot | Page |
Installation |
|
RI9 Rudder Angle Indicator
The RI9 is designed for bulkhead or panel mounting, and should be placed in a location in clear view of the helmsman.
Two or more indicators may be connected in series with the rudder feedback unit.
Note!
If more than one rudder angle indicator is connected, remove the Jumper Switch
For electrical connection of rudder feedback unit and indicator a
Fig.
RI9 Wiring diagram
Calibration
The RI9 indicator is calibrated for voltage input signal (RF14XU Rudder Feedback Unit) and has to be reconnected for current signal from RF45X.
This is done by opening the RI9 and move “jumper” ST3 from “U” to “I” position. See Fig.
Note!
The “Norm”/“Inv” jumper does not affect the meter deflection for current input signal. If the meter deflection has to be reversed, it must be made in the feedback unit as described for RF45X.
Simrad Robertson AS
Egersund - Norway