Simrad ROBERTSON AP45 manual RI9 Wiring diagram

Models: ROBERTSON AP45

1 124
Download 124 pages 5 Kb
Page 81
Image 81

Robertson AP45 Autopilot

Page 5-31

Installation

 

RI9 Rudder Angle Indicator

The RI9 is designed for bulkhead or panel mounting, and should be placed in a location in clear view of the helmsman.

Two or more indicators may be connected in series with the rudder feedback unit.

Note!

If more than one rudder angle indicator is connected, remove the Jumper Switch S1-S2 on J45S PCB.

For electrical connection of rudder feedback unit and indicator a 3-wire cable (3 x 1,5 mm2 - AWG14) should be run. See Fig. 5-37.for connection to junction unit.

Fig. 5-37

RI9 Wiring diagram

Calibration

The RI9 indicator is calibrated for voltage input signal (RF14XU Rudder Feedback Unit) and has to be reconnected for current signal from RF45X.

This is done by opening the RI9 and move “jumper” ST3 from “U” to “I” position. See Fig. 5-38.

Note!

The “Norm”/“Inv” jumper does not affect the meter deflection for current input signal. If the meter deflection has to be reversed, it must be made in the feedback unit as described for RF45X.

Simrad Robertson AS

Egersund - Norway

Page 81
Image 81
Simrad ROBERTSON AP45 manual RI9 Wiring diagram