Robertson AP45 Autopilot

Page 5-9

Installation

 

G40A Gyro Interface Unit

The G40A is required when a Gyro Compass with geared synchro or stepper signal output is connected to AP45. The unit shall be mounted not more than two meters from the AP45 control unit. This is to avoid voltage drop and reduce interference via the interconnecting cables.

All cable conductors are terminated in screw terminals on the G40A PCB. For cabling and connections see Fig. 5-9.For screen termination, see Fig. 5-22.

Fig. 5-9

G40A Gyro Interface Connections

There are also three plug-in straps on the PCB, one for each phase. The position of the straps makes the G40A to operate from either positive or negative step- signals. For setting of the straps, refer to Fig. 5-10.The shown strap position enables step signals with positive common. For negative common, insert strap vertically, A1-A3, A2-A4 and so on.

In addition a DIP switch is included. Switch no. 1 sets gear ratio: 360:1 = switch to 0 (OFF)

90:1 = switch to 1 (ON)

The remaining switches 2, 3 and 4 are for test purpose only and shall be 0 (OFF) for normal use. Refer to table on page 7-3.

For SKR80/82 current loop, switch no. 2 shall be set to ON, the others to OFF. Fig. 5-10shows the location of the switches and LED's.

The potentiometer VR1 is factory set to 2.5V reference voltage, and should not be readjusted.

Simrad Robertson AS

Egersund - Norway

Page 59
Image 59
Simrad ROBERTSON AP45 manual G40A Gyro Interface Connections