Job: |
|
|
|
|
|
|
|
| Hi Delta→ - Type H | ||
|
|
|
|
|
|
| |||||
Engineer: |
|
|
|
|
| Space Heating/Hot Water Boilers | |||||
Contractor: |
|
|
|
|
| ||||||
|
|
|
|
| Models | ||||||
Prepared By: |
| Date: |
|
|
| ||||||
|
|
|
|
| |||||||
Model: |
| Indoor/Outdoor: |
|
| MBTUH Input: | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
100% Factory Fire Tested
Efficiency: 84%
Maximum Outlet Temperature: 230°F
Minimum
Thermal Shock Proof Heat Exchanger
Limited
Limited
Warranty
Diagnostic Center with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Patented Burner Security Blanket
Heat Exchanger
H Stamp
Headers
Bronze – Option
ASME Inspected and Stamped 160 PSIG Working Pressure
National Board Approved
Fin Tubing
Copper – Standard
Cupro Nickel – Option
ASME Steel Tube Sheet
Silicone High Temp.
ASME Pressure Relief Valve
45 PSIG – Standard on Models 302B and 402B
60 PSIG – Standard on Models
PSIG – Optional
Temperature and Pressure Gauge
Water Connections
Left – Standard
Right – Option
Controls
120V, 60Hz, 1∅ Power Supply
120/24V 60Hz Transformer
100%
Hot Surface Ignition
Remote Flame Sensor
High Limit Control, Manual Reset
On/Off Power Switch
Manual
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switch
Economaster Pump Time Delay
Enable/Disable
Gas Train | Burner |
|
|
|
|
|
|
| |||||
| Manual Gas | | |||||||||||
| Gas Pressure Regulator | Temperature Controls |
|
|
|
| |||||||
Safety |
|
|
|
| |||||||||
| Tankstat, | ||||||||||||
| Firing Control Valve |
| |||||||||||
|
|
|
|
|
|
|
|
| |||||
| Firing Mode |
|
|
|
|
|
|
|
|
| |||
| Tankstat, | ||||||||||||
| On/Off (H4): Models |
| |||||||||||
|
| Aquastat, | |||||||||||
| 302B and 402B |
| |||||||||||
|
| B- | TempTracker Digital Controller, | ||||||||||
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||||
|
| B- | TempTracker Digital Controller, | ||||||||||
| Fuel |
| |||||||||||
|
|
|
|
|
|
|
|
| |||||
| Natural Gas |
|
|
|
|
|
|
|
|
| |||
|
| Electronic Sequencer, | |||||||||||
| Propane Gas |
| |||||||||||
|
| Electronic Sequencer, | |||||||||||
| 4” WC Gas Supply Pressure |
| |||||||||||
| Options |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||||||
| Design Certified ANSI Z21.13/ |
| Ignition Module, Manual Reset | ||||||||||
| CSA 4.9 |
| TruSeal→ Direct Vent | ||||||||||
Construction |
| Low Water | |||||||||||
| High Limit Control, Auto Reset | ||||||||||||
| Indoor/Outdoor Construction |
| |||||||||||
| P- |
|
| Pump: |
|
| HP, 120V, 1∅, 60Hz | ||||||
| Enclosed Front Controls |
| |||||||||||
|
|
|
|
| Water Hardness: |
|
| GPG | |||||
Venting |
|
|
|
|
|
| |||||||
|
|
|
|
| Cast Iron |
|
| Bronze | |||||
| Vent Location |
|
|
|
|
| Mounted |
|
| Loose | |||
| Top – Standard |
|
|
|
|
| Front |
|
| Rear | |||
| Rear – Option |
| Cold Water Start (See 2000.48) | ||||||||||
| Vent Termination Cap |
| Low Gas Pressure Switch, Manual | ||||||||||
| Outdoor |
| High Gas Pressure Switch, Manual | ||||||||||
| Indoor, Horizontal |
| SureRack™ Kit |
|
| ||||||||
| Indoor, Vertical (by others) |
| SureRack |
|
| ||||||||
| Combustion Air |
|
|
|
|
|
|
|
|
|
|
|
|
| Regulatory Agency Requirements | ||||||||||||
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Air Intake Elbow |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Extractor – Optional
By others
Not required
Catalog No.: 2000.302D | Effective: | Replaces: |