Raypak H-0180B Inspection And Maintenance Procedures, For Honeywell Valve Turn gas control knob

Models: H-0135B H-0066B H-0180B H-0090B H-0030B H-0042B

1 4
Download 4 pages 24.44 Kb
Page 3
Image 3
5.For Honeywell Valve: Turn gas control knob

FOR INTERMITTENT IGNITION (IID) WITH HONEYWELL OR ROBERTSHAW GAS VALVE (For All Models)

1. STOP! Read the safety information above.

2. Set the thermostat to the lowest setting.

3. Turn off all electric power to the appliance.

4. This boiler is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

GAS CONTROL

KNOB SHOWN

IN "ON" POSITION

GAS INLET

Fig.#8087.0

HONEYWELL (Models 30 - 90)

5.For Honeywell Valve: Turn gas control knob

clockwise TO TURN OFF GAS TO BOILER to "Off".

For Robertshaw Valve: Push in and move gas control lever to "Off" position.

6. Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

7. For Honeywell Valve: Turn gas control counter-

clockwise 3. For Honeywell Valve: to "On".

For Robertshaw Valve: Move gas control lever to "On" position.

GAS CONTROL

KNOB SHOWN

IN "OFF"

POSITION

GAS INLET

Fig. #8934.0

ROBERTSHAW (All Models)

8. Turn on all electric power to the boiler.

9. Set thermostat to desired setting.

10. If the boiler will not operate, follow the instruction "To Turn Off Gas To Boiler" and call your service technician or gas supplier.

TO TURN OFF GAS TO BOILER

1. Set the thermostat at the lowest setting.

2. Turn off all the electric power to the boiler if service

is to be performed.

 

3. For Honeywell Valve:

 

Turn gas control knob clockwise

to "Off".

Make sure knob rest against stop.

 

For Robertshaw Valve:

 

Push in and move gas control lever to "Off" position.

HONEYWELL PILOT

CAUTION: Should overheating occur or the gas sup- ply fails to shut off, DO NOT turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance. Failure to observe this precaution may aggravate the over- heated condition resulting in possible damage to the boiler and injury to the user.

INSPECTION AND MAINTENANCE PROCEDURES

It is a good practice to make a periodic inspection of the boiler. It is recommended that the home owner or user check's the boiler after the first and third month of operation, and then on an annual basis, or more often if desired. It is also recommended to have a qualified service agency check the boiler before each heating season, or at anytime there may be an indica- tion of a problem.

DANGER: Keep boiler area clear and free from combustibles and flammable materials. Do not o b - struct the flow of combustion and ventilating air into the boiler enclosure. Failure to observe these safety precautions can cause fire, explosion, or asphyxia- tion.

BLUE FLAME

Fig.#9295

3

Page 3
Image 3
Raypak H-0180B Inspection And Maintenance Procedures, For Honeywell Valve Turn gas control knob, To Turn Off Gas To Boiler