Raypak NH, 0133-4001 WH manual Indoor Installations, Before, After, Of Drafthood

Models: 0133-4001 WH NH

1 53
Download 53 pages 14.05 Kb
Page 12
Image 12
INDOOR INSTALLATIONS

INDOOR INSTALLATIONS

MODEL 133

Step 1. Shut-off main electrical power switch to heater.

Step 2. Turn heater manual switch, located in upper control panel, to the "OFF" position. Step 3. Shut-off gas supply and water supply to the heater.

Step 4. Mount drafthood on heater and attach with the 8 sheet metal screws provided. Drafthood

should be positioned with the vent sensor located on the front left side as shown.

Step 5. Remove plastic plug from left side of heater jacket and install the plastic grommet provided. Step 6. Route flue sensor wire harness through the grommet installed in Step 5.

Fig. #8946

Step 7. Remove door and locate wire from roll out sensor to High Limit with the male/female connector.

 

 

 

 

BEFORE

 

 

AFTER

 

INSTALLATION

 

INSTALLATION

 

OF DRAFTHOOD

 

OF DRAFTHOOD

Fig. #8947

 

 

 

 

Step 8. Disconnect male/female connector and attach to the 2 wires from drafthood vent sensor harness.

12

Page 12
Image 12
Raypak NH, 0133-4001 WH manual Indoor Installations, Before, After, Of Drafthood