Case 1. Starting failure

 

Check

Probable Causes

 

Action

 

 

 

 

 

 

 

Fuel Tank

Incorrect fuel

 

Drain it and fill with correct fuel

 

 

 

 

 

 

 

Fuel Filter

Fuel filter is clogged

 

Clean

 

 

 

 

 

 

 

Carburetor Adjustment Screw

Out of normal range

 

Adjust to normal range

 

 

 

 

 

 

 

Sparking (no spark)

Spark plug is fouled/ wet

 

Clean/ dry

 

 

 

Plug gap is incorrect

 

Correct (GAP: 0.6 ~ 0.7 mm)

 

 

 

 

 

 

 

Spark Plug

Disconnected

 

Retighten

 

 

 

 

 

Case 2. Engine starts but does not keep running/ hard re-starting.

 

 

 

Check

 

Probable Causes

 

Action

 

 

 

 

 

 

 

 

 

 

Fuel Tank

 

Incorrect fuel

 

Drain it and fill with correct fuel

 

 

 

 

 

 

 

Carburetor Adjustment Screw

 

Out of normal range

 

Adjust to normal range

 

 

 

 

 

 

 

Muffler, Cylinder (exhaust port)

 

Carbon is built-up

 

Wipe away

 

 

 

 

 

 

 

Air Cleaner

 

Clogged with dust

 

Wash

 

 

 

 

 

 

 

Cylinder Fin, Fan Cover

 

Clogged with dust

 

Clean

 

 

 

 

 

 

 

 

 

 

 

 