Redring 550S Redring After Sales Service, What To Do If Things Go Wrong, Professional Service

Models: 550S

1 12
Download 12 pages 39.66 Kb
Page 6
Image 6
PROFESSIONAL SERVICE

WHAT TO DO IF THINGS GO WRONG (2)

PROFESSIONAL SERVICE

If the previous “Self Help” checks fail to restore the performance, you should seek professional help.

The person who installed the shower is probably the best one to repair it and is certainly the person to contact if you have had a problem in the guarantee period.

The following additional checklist is provided for the benefit of the qualified service person.

WARNING: SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR BEFORE REMOVING THE COVER TO MAKE CHECKS

Water too HOT

Water flow restricted by blockage in filter of solenoid valve.

 

Switch off water, loosen inlet connection to solenoid, remove filter in solenoid

 

with long nosed pliers and flush clean.

 

 

Water too COLD

Check circuit through thermal cut-out.

 

Check circuit through microswitches on the pressure switch.

 

Check each element circuit.

 

Check tightness of electrical connections.

 

 

No control over

Check Drive Gite is correctly engaged into Control Knob (see diagram.9)

water flow

Undo headworks of stabiliser valve.

 

Check stabiliser is in place and remove any debris in valve.

Water leaks from

Check for cause of high pressure and remove it.

burst pressure

Blockage on outlet e.g. blocked shower handset.

relief valve

Replace the pressure relief disc (not covered by guarantee).

 

 

Water does not

Check circuit through solenoid coil. If defective then replace.

flow when button

Check circuit through microswitches. If defective then replace.

“A”, “B” or “C” is

Power supply not reaching shower.

pressed.

 

 

 

REDRING AFTER SALES SERVICE

We offer a technical advisory service on the telephone to contractors and other customers with problems in the field.

RING 08709 000430 (UK ONLY)

RING YOUR LOCAL DEALER (Export Variants)

Some spare parts (see later section) can be supplied against Credit or Debit cards.

RING 08709 000420 (UK ONLY)

Remember to quote the exact type of shower, as written on the front of the shower and on this leaflet.

The model and serial number are located on the bottom face of the shower.

Make a note of those numbers here, and be sure to quote them if you call for advice.

Model Number: 53-67_ _ _ _ _ _ _ _ _ _ _ _ _ _

Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _