Fixing the unit on the wall

Fixing the unit on the wall

Use the wall mounting bracket supplied and the two lower fixing holes.

An extra top fixing point is available by temporarily removing the condenser assembly.

Connecting the water supply and vent pipes

When the unit is fixed to the wall, make the final water supply and steam vent connections and secure the pipe work.

Switch the water supply back on.

Connecting the mains cable

Ensure the mains supply is isolated.

Connect the mains cable from the SB2 to the 13 Amp fused isolating switch. Ensure

the cable clamps are firmly secured and the cable ends are tightened into the terminal block.

Note: The supply cable must be a minimum of 1.0mm2 three core multi strand PVC insulated mains cable. The terminal block will not accept cable diameters above 1.5mm2. Check that the mains supply matches the electrical rating on the product. The rating plate is located on the bottom edge of the unit.

IMPORTANT: Connect the supply cable, complying with BS6500, to this appliance in accordance with the following code:

GREEN AND YELLOW (EARTH) connect to terminal marked " Connecting the water supply and vent pipes ".

BLUE (NEUTRAL) connect to terminal marked "N"

BROWN (LIVE) connect to terminal marked "L"

WARNING: THIS APPLIANCE, AND ALL METAL PIPE WORK CONNECTED TO IT, MUST BE EARTHED.

Replacing the front cover

Support the cover and re-attach the flying lead to the unit (See Fig. 5a and Fig. 5b).

Replace the front cover and secure using the top and bottom fixing screws.

Carefully replace the knob, ensuring correct alignment of the D shaft.

Reconnect the mains supply.

Schematic

Wiring

Diagram