Redring LP330, L318 manual Installing The Appliance, Filling Point, Typical System Diagrams

Models: LP330 L318

1 13
Download 13 pages 57.24 Kb
Page 5
Image 5
Filling Point

Example: 30L system total capacity requires an expansion vessel capacity of

30 x 0.0833 = 2.5 litres with a 0.5 bar vessel charge and system cold fill pressure.

Filling Point

The heating system must be provided with a suitable filling mechanism to both complete the initia l fill and top up the system if necessary. The filling device must comply with Water Supply (water fittings) Regulations and the local Water Authority Regulations. Refer to BS 5376: for guidance.

Typical System Diagrams

Thermostatic radiator valves should NOT be used with this boiler.

The boiler is designed for small sealed heating systems usually operating within a single room.

4.Installing The Appliance

Unpacking The Appliance

Unpack the appliance and check the contents with the list below.

1

Boiler

4

Screws

4

Rawlplugs

1Installation & Servicing Instructions including Guarantee

1Plug in 24 hour timer

Page 5 of 13

Page 5
Image 5
Redring LP330, L318 manual Installing The Appliance, Filling Point, Typical System Diagrams, Unpacking The Appliance