Regency F2402M manual Recommended Heights for Woodstove Flue, Recommended Flue Height

Models: F2402M

1 28
Download 28 pages 15.25 Kb
Page 13
Image 13

INSTALLATION

RECOMMENDED HEIGHTS FOR

WOODSTOVE FLUE

Simple rules on draft. See Table 1.

1)At sea level minimum height is 12' (3.7m) straight.

2)Add the following vertical height to compen-

sate for:

 

45 deg. elbow

= 1 ft. (.3m)

90 deg. elbow

= 2 ft. (.6m)

"T"

= 3 ft. (.9m)

Each foot of horizontal run = 2 ft. (.6m)

3) Add 4% overall for each 1000' (3.5m) above

Recommended Flue Height

sea level.

 

Elevation

Example a)

Example b)

Example: a)

 

0' (0m)

18' (5.5m)

 

21' (6.4m)

 

1000' (305m)

18.72' (5.7m)

21.84' (6.7m)

1-1/2 ft. of horizontal run

= 3 ft. (.9m)

2000' (610m)

19.44' (5.9m)

22.68' (6.9m)

one "T"

= 3 ft. (.9m)

5000' (1524m)

21.60' (6.6m)

25.20' (7.7m)

Total Addition (at sea level)

= 6 ft. (1.8m)

8000' (2438m)

23.76' (7.2m)

27.72' (8.5m)

Example: b)

 

 

 

 

 

One 90 deg. elbow

= 2 ft. (.6m)

 

 

 

 

2 ft. of horizontal run

= 4 ft. (1.2m)

 

 

 

 

one "T"

= 3 ft. (.9m)

 

 

 

 

Total Addition (at sea level)

= 9 ft. (2.7m)

 

 

 

 

TABLE 1

MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET

(Measured from the top of the unit)

ELEVATION (FT)

 

 

# OF ELBOWS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABOVE SEA LEVEL

0

2 x 15o

4 x 15o

2 x 30o

4 x 30o

2 x 45o

4 x 45o

 

 

 

 

 

 

 

 

 

 

 

0-1000

 

12.0

13.0

14.0

15.0

18.0

16.0

20.0

 

1000-2000

 

12.5

13.5

14.5

15.5

19.0

16.5

21.0

 

2000-3000

 

13.0

14.0

15.0

16.0

19.5

17.0

21.5

 

3000-4000

 

13.5

14.5

15.5

17.0

20.0

18.0

22.5

 

4000-5000

 

14.0

15.0

16.0

17.5

21.0

18.5

23.0

 

5000-6000

 

14.5

15.5

17.0

18.0

21.5

19.0

24.0

 

6000-7000

 

15.0

16.0

17.5

18.5

22.5

20.0

25.0

 

7000-8000

 

15.5

16.5

18.0

19.0

23.0

20.5

25.5

 

8000-9000

 

16.0

17.0

18.5

20.0

24.0

21.0

26.5

 

9000-10000

 

16.5

17.5

19.0

20.5

24.5

22.0

27.0

 

 

 

 

 

 

 

 

 

 

 

NOTE: No more than two offsets (four elbows) allowed. Two 45o elbows equal one 90o elbow.

Regency Freestanding Woodstove

13

Page 13
Image 13
Regency F2402M manual Recommended Heights for Woodstove Flue, Recommended Flue Height, Elevation Example a Example b