INSTALLATION
COMBUSTIBLE WALL CHIMNEY
CONNECTOR PASS-THROUGHS
Minimum chimney clearance to brick and combustibles 2 in. (50.8mm)
Method A: 12" (304.8 mm) Clearance to Combustible Wall Member:
Using a minimum thickness 3.5" (89 mm) brick and a 5/8" (15.9 mm) minimum wall thickness clay liner, construct a wall
mm)of brick masonry between the clay liner and wall combustibles. The clay liner shall run from the brick masonry outer surface to the inner surface of the chimney fl ue liner but not past the inner surface. Firmly grout or cement the clay liner in place to the chimney fl ue liner.
Method B: 9" (228.6 mm) Clearance to Combustible Wall Member:
Using a 6" (152.4 mm) inside diameter, listed,
Method C: 6" (152.4 mm) Clearance to Combustible Wall Member:
Starting with a minimum 24 gage (.024" [.61 mm]) 6" (152.4 mm) metal chimney connector, and a minimum 24 gage ventilated wall thimble which has two air channels of 1" (25.4 mm) each, construct a wall
mm)space. There should also be a support sized to fi t and hold the metal chimney connector. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure the metal chimney connector do not penetrate chimney fl ue liner.
Method D: 2" (50.8 mm) Clearance to Combustible Wall Member:
Start with a
Minimum
12 in. (304.8mm) to combustibles
Chimney Flue
Masonry chimney
Minimum clearance 12 in. (304.8mm) of brick
Chimney |
connector |
Fire clay liner
12 | Regency Freestanding Woodstove |