OPERATING INSTRUCTIONS

CONTROL BOARD FUNCTIONS

1.AUGER TRIM:

Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the feed rate to 4 seconds ON time Auger pulse. This is done only on LOW to allow the burning of poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On time to 2 sec- ond. This setting is for high-grade fuel only. Push the button until just the number 1 light is on, this is for a three (3) second on time (standard setting).

2.CONVECTION BLOWER CONTROL:

Used to turn the convection blower ON/OFF. Leave the convection blower ON for peak efficiency.

3.AUGER PULSE LIGHT:

This light will flash in conjunction with the auger. The light comes on when auger turns.

4.MANUAL AUGER FEED:

If the unit runs out of fuel, this button can be used to “prime the auger system”. This button will turn off after 60 seconds and then must be released and pressed again.

5.SYSTEM LIGHT:

Responsible for signaling the state of the control board. When the light is flashing during start-up, the stove is in an automatic start mode. When the light is solid, the Heat Level Setting can be altered.

6.ON/OFF BUTTON:

Used to turn the unit ON and OFF.

7.HEAT LEVEL ADJUSTMENT:

When pressed, will change the heat setting of the unit from low to high.

8.HEAT OUTPUT INDICATOR:

Shows the present heat output setting.

9.CONTROL MODE SWITCH:

Used to set the unit’s controls to one of three mode settings; manual, high/low, or auto/off.

 

 

HIGH/LOW

 

 

AUTO/OFF

MANUAL

 

9

 

 

 

 

 

 

 

1

 

 

 

AUGER TRIM

 

8

 

FAN

2

 

 

 

 

 

 

 

 

3

OPERATION

 

 

AUGER

4

 

 

 

5

 

 

 

 

7

HEAT

ON/OFF

6

 

LEVEL

 

 

 

 

GF55-008

 

Figure 3: Circuit Board Control Panel Decal.

AUTOMATIC SAFETY FEATURES

A.The stove and insert have a low limit safety switch located on the housing of the exhaust blower. If the exhaust temperatures drop below 120°F (49°C) the unit will shut down and will be required to go through a full start up procedure again.

The most common cause for this is an empty hopper. This switch should only be by-passed for testing purposes by a technician.

B.The stove and insert have a high limit safety switch located just below the hopper behind the external body panels. If the temperature of this switch reaches 200°F (93°C), the auger will stop feeding fuel and as the exhaust temperatures drop below 120°F (49°C), the unit will shut down.

The 200°F (93°C) switch is a manual reset and should only be reset by a service person who can first diagnose the reason for failure.

The two most likely causes are Convection Fan failure or High Limit Switch failure. Either one needs to be properly diagnosed and rectified. Since this is a safety switch it should never be by-passed for any reason other than the service technician to test the operation.

Greenfire Pellet Stove and Insert Owner's Manual

7

Page 7
Image 7
Regency GFI55 owner manual Operating Instructions, Control Board Functions, Automatic Safety Features

GFI55 specifications

The Regency GFI55 is a remarkable gas fireplace insert that combines elegance with advanced technology, offering warmth and style to any home setting. It is engineered for efficient heating, making it an excellent choice for those seeking to enhance their living spaces with both functionality and aesthetic appeal.

One of the standout features of the GFI55 is its impressive heating capacity. With an output of up to 40,000 BTUs, it is capable of heating larger areas effectively, providing cozy warmth even in expansive rooms. This makes it ideal for open-concept designs where the heat must be distributed evenly.

The design of the GFI55 is both classic and contemporary, featuring a large viewing area that showcases the mesmerizing flames. The flame presentation is enhanced by ceramic logs, which not only look realistic but also contribute to the fireplace's overall efficiency by retaining heat.

Technologically, the Regency GFI55 boasts a range of innovative features. It includes a high-efficiency heat exchanger which maximizes heat output while minimizing energy consumption, ensuring that users enjoy warmth without excessive energy bills.

Safety is also a priority in the design of the GFI55. It is equipped with an automatic shut-off feature that activates in case of overheating, providing peace of mind for families. Additionally, the unit meets stringent safety standards, ensuring that it is a secure option for residential use.

Installation is made easy with the GFI55, which can fit into most standard fireplace openings, allowing for a straightforward retrofit into existing masonry fireplaces. This adaptability makes it an appealing choice for homeowners looking to upgrade their current heating solutions without the need for extensive renovations.

Moreover, the GFI55 offers customizable options to suit individual tastes. Homeowners can choose from different finishes and decorative trims, ensuring that the fireplace complements their home's interior design.

In summary, the Regency GFI55 gas fireplace insert is an exceptional product that marries advanced technology with elegant design. Its efficient heating capabilities, safety features, and customization options make it an excellent investment for anyone looking to enhance their home's ambiance and comfort.