INSTALLATION
Position the grill on the inside bodyface side and fastenusingthebolts,washersandnutsprovided (2 per side) as shown in the diagrams.
Note: The grillhasafrontandrear,theholes on the front side have rounded edges and the rear holes have flat edges.
View from Rear of Insert
OPTIONAL FLUE
CONNECTOR KIT
The optional Flue ConnectorKit (Part#
MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES
The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below.
| Adjacent | Mantle** | Top | Side | Minimum | Minimum | Minimum |
Unit | Side Wall | (to Top) | Facing | Facing | Hearth | Hearth | Hearth Side |
| (to Side) |
| (to Top) | (to Side) | Extension* | Thickness* | Extension |
| A | B | C | D | E | F | G |
Small Flush |
|
|
|
|
|
|
|
Insert (I1100S) | 15"/380mm | 20"/510mm | 14"/355mm | 7.375"/187mm | 16"/406mm | 1.5"/38mm | 8"/205mm |
|
|
|
|
|
|
|
|
Large Flush |
|
|
|
|
|
|
|
Insert (I3100L) | 13"/330mm | 19"/480mm | 18"/455mm | 6.5"/165mm | 16"/406mm | 1.5"/38mm | 8"/205mm |
|
|
|
|
|
|
|
|
Hearth Heater |
|
|
|
|
|
|
|
(H2100M) | 10"/255mm | 25"/635 mm | 14"/355mm | 8.5"/216mm | 18"/455mm | 1.5"/38mm | 6"/152mm |
|
|
|
|
|
|
|
|
Side and Top facing is a maximum of 1.5" thick.
Floor protection must
*If the hearth extension is fl ush with the fl oor
(F)it must extend 19.5" in front of the body
face (E).
Note: Hearth Extension Width (G) is meas- ured from edge of fuel door to side of hearth.
** A
Clearance diagram for installations
Regency Wood Insert & Hearth Heater | 7 |