Position the grill on the inside bodyface side and fastenusingthebolts,washersandnutsprovided (2 per side) as shown in the diagrams.

Note: The grillhasafrontandrear,theholes on the front side have rounded edges and the rear holes have flat edges.

View from Rear of Insert

OPTIONAL FLUE

CONNECTOR KIT

The optional Flue ConnectorKit (Part# 846-527) and the Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your flue connector and the insert collar. Detailed installation instructions are included with the kit.

MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES

The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below.

 

Adjacent

Mantle**

Top

Side

Minimum

Minimum

Minimum

Unit

Side Wall

(to Top)

Facing

Facing

Hearth

Hearth

Hearth Side

 

(to Side)

 

(to Top)

(to Side)

Extension*

Thickness*

Extension

 

A

B

C

D

E

F

G

Small Flush

 

 

 

 

 

 

 

Insert (I1100S)

15"/380mm

20"/510mm

14"/355mm

7.375"/187mm

16"/406mm

1.5"/38mm

8"/205mm

 

 

 

 

 

 

 

 

Large Flush

 

 

 

 

 

 

 

Insert (I3100L)

13"/330mm

19"/480mm

18"/455mm

6.5"/165mm

16"/406mm

1.5"/38mm

8"/205mm

 

 

 

 

 

 

 

 

Hearth Heater

 

 

 

 

 

 

 

(H2100M)

10"/255mm

25"/635 mm

14"/355mm

8.5"/216mm

18"/455mm

1.5"/38mm

6"/152mm

 

 

 

 

 

 

 

 

Side and Top facing is a maximum of 1.5" thick.

Floor protection must non-combustible, insula- tive material with an R value of 1.1 or greater.

*If the hearth extension is fl ush with the fl oor

(F)it must extend 19.5" in front of the body

face (E).

Note: Hearth Extension Width (G) is meas- ured from edge of fuel door to side of hearth.

** A non-combustible mantel may be in- stalled at a lower height if the framing is made of metal studs covered with a non-combustible board.

Clearance diagram for installations

Regency Wood Insert & Hearth Heater

7

Page 7
Image 7
Regency I3100L Installation, Optional Flue Connector Kit, Masonry And Factory Built Fireplace Clearances, Small Flush