MAINTENANCE

6)

Do not permit creosote or soot buildup in the

 

chimney system. Check and clean chimney

 

at regular intervals.

7)

Your Regency Insert can be very hot. You

 

may be seriously burned if you touch the

 

insert while it is operating. Warn children of

 

the burn hazard.

8)

The insert consumes air while operating,

 

provide adequate ventilation with an air

 

duct or open a window while the insert is

 

in use.

9)

Do not use grates, irons or other methods

 

for supporting fuel. Burn directly on the

Removal for Cleaning etc.

Removal of your insert for cleaning purposes is usually not required if a proper installation has been done. In the event that removal is re- quired, be sure not to damage any parts needed for re-installation. In most cases removal and replacement of the baffl e system should allow full access for cleaning.

WARNING: Thingstorememberincase of chimney fire:

1)Close draft control

2)Call the Fire Department

DOOR LATCH

ADJUSTMENT

The door latch may require adjustment as the door gasket material compresses after a few

res. Removal of the spacer washer, shown in the diagram below, will allow the latch to be moved closer to the door frame, causing a tighter seal. Remove and replace the nuts, washer as shown.

bricks.

10) Open the draft control fully for 10 to 15

seconds prior to slowly opening the door

when refuelling the fi re.

11) Do not connect your unit to any air distribu-

tion duct.

12) Your insert should burn dry, standard fi re-

wood only. The use of “mill ends” is discour-

aged as this fuel can easily overheat your

insert. Evidence of excessive overheating

will void your warranty. As well, a large

portion of sawmill waste is chemically

treated lumber, which is illegal to burn in

many areas. Chemically treated fi re logs

also must not be burned in your insert.

13) Do not store any fuel closer than 2 feet from

your unit.

14) Do not burn salt drift wood as it will corrode

your unit and void the warranty.

15) Do not operate the unit if the glass is broken

or missing. Do not operate the unit if the

gasketing is worn out and not sealing the

door or the glass.

It is very important to carefully maintain your insert, including burning seasoned wood and maintaining a clean stove and chimney system. Have the chimney cleaned before the burning season and as necessary during the season, as creosote deposits may build up rapidly. Moving parts of your insert require no lubrication.

CREOSOTE

When wood is burned slowly, it produces tar and other organic vapors, which form creosote when combined with moisture. The creosote vapors

Ways to Prevent and

Keep Unit Free of Creosote

1)Burn insert with draft control wide open for about15minuteseverymorningduringburn- ing season. This helps to prevent creosote deposits within the heating system.

2)Burn insert with draft control wide open for about 10 - 15 minutes every time you add fresh wood. This allows the wood to achieve the charcoal stage faster and burns up any wood vapors which might otherwise be deposited within the system.

3)Only burn seasoned wood! Avoid burning wet or green wood. Seasoned wood has been dried at least one year.

4)A small hot fi re is preferable to a large smouldering one that can deposit creosote within the system.

5)Check the chimney at least twice a month during the burning season for creosote build-up.

6)Have chimney system and unit cleaned by competent chimney sweeps twice a year during the fi rst year of use and at least once a year thereafter or when needed.

MAINTENANCE OF

GOLD-PLATED DOORS

The gold electroplated fi nish on the doors requires little maintenance, and need only be cleanedwithadampcloth.DONOTuseabrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty.

GLASS CLEANING

Only clean your glass window when it is cool. Your local retailer can supply you with special glass cleaner if plain water and a soft cloth does not remove all deposits.

GLASS

REPLACEMENT

Your Regency Insert is supplied with 5 mm. Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact

-purchase your replacement from an authorized Regencydealeronly,andfollowourstep-by-step instructions.

GLASS REMOVAL

Allowthestovetocoolbeforeremovingorreplac- ing glass. Remove the door from the insert and remove the glass retainer. Use caution when removing broken glass to prevent injury.

When placing the replacement glass in the door, make sure that the glass gasketing will properly seal your unit. Replace the retainer and tighten securely, but do not wrench down on the glass as this may cause breakage. Do not substitute materials. If your glass door does break, do not continue to use your unit until it has been replaced.

condense in the relatively cool chimney fl ue of a slow-burning fi re. As a result, creosote residue accumulatesonthefluelining.Whenignited,this creosote can make an extremely hot fi re.

DOOR GASKET

If the door gasket requires replacement, 7/8" diameter material must be used. A proper high temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local Regency dealer.

14

Regency Wood Insert & Hearth Heater

Page 14
Image 14
Regency I1100S, H2100, I3100L installation manual Maintenance

H2100, I1100S, I3100L specifications

The Regency H2100 and I3100L are two innovative and efficient heating solutions that cater to the evolving needs of modern homes. Known for their quality craftsmanship and advanced technology, these products have become favorable choices among homeowners seeking both aesthetics and functionality.

The Regency H2100 is a gas fireplace insert designed specifically to be installed within an existing fireplace. It features a sleek and contemporary design that enhances the ambiance of any room while providing effective heating. One of the main highlights of the H2100 model is its high efficiency rating, often exceeding 70%. This efficiency translates to reduced energy costs and a minimal environmental footprint. Equipped with a powerful heating capacity, the H2100 can effectively warm spaces up to 1,500 square feet, ensuring comfort during the coldest months.

Key technologies integrated into the H2100 include a direct vent system that allows for safe and efficient exhaust of combustion gases, promoting clean indoor air quality. Additionally, the unit features adjustable flame settings and an easy-to-use remote control, allowing for customized heating options to meet individual preferences. The H2100 also includes a variety of aesthetic options, such as different media choices, decorative surrounds, and glass doors, making it suitable for diverse interior designs.

On the other hand, the Regency I3100L is a wood-burning insert designed for homeowners who appreciate traditional heating methods. This model boasts a large firebox that can accommodate larger logs, providing extended burn times and minimal need for refueling. With an impressive efficiency rating, the I3100L minimizes wood consumption while maximizing heat output.

One of the standout characteristics of the I3100L is its large viewing glass, offering an unobstructed view of the fire, creating an inviting atmosphere. The insert features secondary combustion technology, which ensures that smoke and emissions are significantly reduced, promoting environmental friendliness. With its classic cast iron construction, durability is another crucial feature, ensuring that the insert will withstand the test of time while providing consistent warmth.

In conclusion, both the Regency H2100 and I3100L present unique heating solutions tailored to different preferences and lifestyles. With their advanced features, energy efficiency, and customizable designs, these models stand out in the market, offering homeowners the perfect blend of comfort, style, and sustainability in their heating solutions. Whether one prefers the convenience of gas or the charm of wood-burning, Regency has positioned itself as a leader in innovative heating technology.