Wood Fireplaces
Gravity Air Feed Kit Option
The Gravity Air Feed Kit is designed to extend the heat output vent above the R90 to the front or the side. The upper louver opening is blocked off and fl ex vent is connected to the vent holes in the top of the unit and run to discharge vent grilles. Both 8" (203mm) diameter insulated Flex vents must be used along with one 30 sq. inch (194cm2) chase vent grill to bring additional air into the chase (for U.S. installations only).
Qty Description
4Connector Collars
4Adjustable Clamps
25’ lengths of fl exible vent pipe (8” dia.)
2Insulated Sleeves
1Block Off Plate
2Discharge Vent Mounting Frames
7
216 x 8 Discharge Vent Grilles
4#8 Drywall Anchors
4Insulation Strips
1Chase Vent Frame (for U.S. installations only)
18 x 8 Chase Vent Grille (for U.S. installations only)
|
|
| Ceiling | 6" (152mm) Min. |
|
|
| To Rouch Opening | |
|
|
| Flue | |
|
|
|
| |
|
|
|
| |
| Connector | Flex Vent |
| of Vent |
| Collar |
|
|
|
| Insulation |
|
|
|
| Strips |
|
|
|
|
|
|
| Vent Cover 'A" |
|
|
|
| Vent Cover 'B' |
|
| Clamp |
| (Inside) |
|
| Connector |
|
|
|
| Collar |
| Base of Stove |
|
|
|
| |
Discharge Vent |
|
|
| |
Grill | Outside Air |
|
|
|
Intake |
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| (replace top louver) |
| Chase Vent |
| Alternate Position for | |
| Grill |
| ||
|
| Chase Vent Grill | ||
|
|
|
30 sq.in. (194 sq.cm) opening
1)Remove the screw from the vent hole cover (vent cover 'A') on top of the unit.
2)Take the connector collar and press and rotate it into the hole to cut through the insulation layer. Remove the collar and remove insulation from the collar. The screws for the inner cover should be exposed.
3)Remove the screws from the inner cover (vent cover 'B') and slide it back under the insulation.
4)Extend flex vent and pull the insulation sleeves over the 8” (203mm) diameter fl ex vents. Leave a short section of fl ex vent exposed at each end. On one end insert the collar into the fl ex vent and use a clamp to hold the fl ex vent in place.
5)Use tin snips to cut slits into the rim of the connector collar. A minimum of four tabs will be required so cut the slits 1” (25mm) (i.e. 1” (25mm) wide tabs) apart around the perimeter of the collar.
6)Install the connecting collar into the top of the unit until the bead of the collar rests against the top of the inner top of the unit. Reach inside the upper louver opening and use pliers to bend the tabs (minimum 4) out on the connector collar. A hammer may be required to lightly tap the tabs and bend them so that they fi t tightly against the bottom of the inner top. Pull the insulation sleeve down to the top of the unit. Repeat steps
June 2007 Regency Product Specifications Book
R90 Wood Fireplace
Flex Vent
7)Position the vent frames for the Discharge Grilles into the rough opening of the stud wall framing. Make sure to add two insulation strips behind the fl anges of the frame prior to securing to wall. The frames will fit between studs framed at 16” (406mm) on center. Use 4 nails or screws to mount the frame to the stud framing.
Insulation
StripsConnecting
Collar
Discharge | Flex | |
Vent | ||
Vent Grille | ||
Clamp | ||
|
Discharge Vent
Frame
8)Insert the connecting collar into the other end of the 5 ft. (1.5m) fl ex vent and use an adjustable clamp to hold the vent in place. Cut tabs into the rim of the connector collar (a minimum of 4 tabs will be required). Push the collar through the 8” (203mm) hole in the mounting frame. Use pliers to bend out tabs (minimum 4) to secure the collar to the mounting frame.
9)Pull the insulation sleeve up the flex vent to the back of the mounting frame. The fl ex vent should now be connected to both the unit and the mounting frames securely. Repeat steps
10)Install the
NOTE: Make sure the
11)The rough opening size for the Chase Vent Grille is 3” H x 10” W (76mm H x 254mm W).
WARNING: A chase vent of 30 sq. inches (194 cm2) MUSTbeinstalledinallapplications,otherwiseserious overheating of the chase may result. Use the chase vent supplied with the R90 unit only or any equivalent one with the same or less restriction of air flow.
12)Recheck all fl ex
13)Install the Chase Vent Grille and install the Discharge Vent Grilles for the hot air outlets.
NOTE: There must be a minimum of 5" (127mm) between the gravity air vents.
173
Wood Fireplaces