Regency R90 dimensions Gravity Air Feed Kit Option, Wood Fireplaces, Qty Description

Models: R90

1 3
Download 3 pages 21.14 Kb
Page 3
Image 3
Gravity Air Feed Kit Option

Wood Fireplaces

Gravity Air Feed Kit Option

The Gravity Air Feed Kit is designed to extend the heat output vent above the R90 to the front or the side. The upper louver opening is blocked off and fl ex vent is connected to the vent holes in the top of the unit and run to discharge vent grilles. Both 8" (203mm) diameter insulated Flex vents must be used along with one 30 sq. inch (194cm2) chase vent grill to bring additional air into the chase (for U.S. installations only).

Qty Description

4Connector Collars

4Adjustable Clamps

25’ lengths of fl exible vent pipe (8” dia.)

2Insulated Sleeves

1Block Off Plate

2Discharge Vent Mounting Frames

71/4-20 x 1/2” Truss Head Screws (used for EX90/R90 only)

216 x 8 Discharge Vent Grilles

4#8 Drywall Anchors

4Insulation Strips

1Chase Vent Frame (for U.S. installations only)

18 x 8 Chase Vent Grille (for U.S. installations only)

 

 

 

Ceiling

6" (152mm) Min.

 

 

 

To Rouch Opening

 

 

 

Flue

 

 

 

 

 

 

 

 

Center-line

 

Connector

Flex Vent

 

of Vent

 

Collar

 

 

 

 

Insulation

 

 

 

 

Strips

 

 

 

 

 

 

 

Vent Cover 'A"

 

 

 

 

Vent Cover 'B'

 

 

Clamp

 

(Inside)

 

 

Connector

 

 

 

 

Collar

 

Base of Stove

 

 

 

 

Discharge Vent

 

 

 

Grill

Outside Air

 

 

 

Intake

 

 

 

 

 

 

 

 

 

 

 

Block-off Plate

 

 

 

 

(replace top louver)

 

Chase Vent

 

Alternate Position for

 

Grill

 

 

 

Chase Vent Grill

 

 

 

30 sq.in. (194 sq.cm) opening

1)Remove the screw from the vent hole cover (vent cover 'A') on top of the unit.

2)Take the connector collar and press and rotate it into the hole to cut through the insulation layer. Remove the collar and remove insulation from the collar. The screws for the inner cover should be exposed.

3)Remove the screws from the inner cover (vent cover 'B') and slide it back under the insulation.

4)Extend flex vent and pull the insulation sleeves over the 8” (203mm) diameter fl ex vents. Leave a short section of fl ex vent exposed at each end. On one end insert the collar into the fl ex vent and use a clamp to hold the fl ex vent in place.

5)Use tin snips to cut slits into the rim of the connector collar. A minimum of four tabs will be required so cut the slits 1” (25mm) (i.e. 1” (25mm) wide tabs) apart around the perimeter of the collar.

6)Install the connecting collar into the top of the unit until the bead of the collar rests against the top of the inner top of the unit. Reach inside the upper louver opening and use pliers to bend the tabs (minimum 4) out on the connector collar. A hammer may be required to lightly tap the tabs and bend them so that they fi t tightly against the bottom of the inner top. Pull the insulation sleeve down to the top of the unit. Repeat steps 1-6 for the second fl ex vent and collar assembly.

June 2007 Regency Product Specifications Book

R90 Wood Fireplace

Flex Vent

7)Position the vent frames for the Discharge Grilles into the rough opening of the stud wall framing. Make sure to add two insulation strips behind the fl anges of the frame prior to securing to wall. The frames will fit between studs framed at 16” (406mm) on center. Use 4 nails or screws to mount the frame to the stud framing.

Insulation

StripsConnecting

Collar

Discharge

Flex

Vent

Vent Grille

Clamp

 

Discharge Vent

Frame

8)Insert the connecting collar into the other end of the 5 ft. (1.5m) fl ex vent and use an adjustable clamp to hold the vent in place. Cut tabs into the rim of the connector collar (a minimum of 4 tabs will be required). Push the collar through the 8” (203mm) hole in the mounting frame. Use pliers to bend out tabs (minimum 4) to secure the collar to the mounting frame.

9)Pull the insulation sleeve up the flex vent to the back of the mounting frame. The fl ex vent should now be connected to both the unit and the mounting frames securely. Repeat steps 1-8 for the second flex vent assembly.

10)Install the block-off plate to the unit. The block-off plate will cover the upper louver opening of the unit and force the fan air to circulate through the two 8” (203mm) diameter fl ex vents. Put high temperature sealant onto the block-off plate. Mount the block-off plate onto the front of the unit and cover the upper louver opening. Make sure that all exposed holes in the block-off plate are sealed with high temperature sealant

NOTE: Make sure the block-off plate is flush and fastened tightly to the Regency R90 Fireplace.

11)The rough opening size for the Chase Vent Grille is 3” H x 10” W (76mm H x 254mm W).

WARNING: A chase vent of 30 sq. inches (194 cm2) MUSTbeinstalledinallapplications,otherwiseserious overheating of the chase may result. Use the chase vent supplied with the R90 unit only or any equivalent one with the same or less restriction of air flow.

12)Recheck all fl ex vent-work connections to make sure that they are secure. Install wall sheathing and cut-out openings for the chase ventilation, and hot air discharge outlets.

13)Install the Chase Vent Grille and install the Discharge Vent Grilles for the hot air outlets.

NOTE: There must be a minimum of 5" (127mm) between the gravity air vents.

173

Wood Fireplaces

Page 3
Image 3
Regency R90 Gravity Air Feed Kit Option, Wood Fireplaces, Qty Description, June 2007 Regency Product Specifications Book