Regency® U38-1 ULTIMATE Freestanding Gas Stove 13
LOG SET INSTALLATION
Read the instructions below carefully and
refer to the diagrams. If logs are broken
do not use the unit until they are replaced.
Broken logs can interfere with the pilot
operation.
The gas log kit contains the following:
a) 02-65 Rear Log
b) 02-56 Middle Left Log
c) 02-44 Front Left Log
d) 02-46 Left Top Log
e) 02-45 Front Right Log
f) 02-47 Center Log
g) 02-48 Middle Right Log
h) Embers 902-151
i) Lava 902-154
Embers. Embers
The "02" refer numbers (i.e. 02-65) are
molded into the rear of each log.
1) Carefully remove the logs from the box and
unwrap them. The logs are fragile, handle
with care - do not force into position.
2) Sprinkle the embers on the left and right
sides of the fi rebox base.
CONVERSION TO LOWER BTU RATINGTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Natural Gas Conversion Kit 730-920
Contains:
Qty. Part # Description
1 904-240 Burner Orifi ce #37 (NG)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet
Propane Conversion Kit 730-922
Contains:
Qty. Part # Description
1 904-390 Burner Orifi ce #52 (Propane)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet
1) Shut off the gas supply.
2) Open the front door. Carefully remove the
logs and lava rock.
3) Remove burner. See diagram below.
Burner Orifi ce
Note: Use a
magnetic type
screwdriver if possible.
Move Rear Log
Pins forward to
front holes.
Vent Restrictor setting at High 40,000 Btu/h
Vent Restrictor setting at Low 30,000 Btu/h
INSTALLATION
4) Unscrew the 2 Rear
Log Pins and move
to the front hole
position.
5) Remove Rear Log
Bracket and slide
the Log Bracket
Restrictor between
the Rear Log Brack-
et and the burner,
secure with the 2
screws.
7) Reinstall new burner orifi ce (NG stamped
#37 or LP stamped #52) and tighten.
8) Reverse steps 3) and 2).
9) Adjust Vent restrictor setting: To set the Vent
restriction as indicated in the diagram, simply
loosen the screws and push the vent restric-
tor plate to the correct position. Tighten the
screws.
Unit Btu/h Restrictor Opening
U38-1 40,000 A 1-3/8" (35mm)
U38-1 30,000 B 1-1/8" (29mm)
6) Remove burner orifi ce with a 1/2" wrench
and discard.
10) Attach the label "This unit has been con-
verted to..." on top of the Serial # decal over
the higher Btu information.
11) Check for gas leaks.
12) Check inlet and outlet pressures.
13) Check operation of fl ame control. Check
for proper fl ame appearance and glow on