Regency Wraps U38-LP, U38-NG Maintenance Instructions, Glass Replacement, Log Replacement

Models: U38-LP U38-NG

1 24
Download 24 pages 42.42 Kb
Page 17
Image 17
MAINTENANCE

MAINTENANCE

MAINTENANCE

INSTRUCTIONS

1) Always shut the valve off before cleaning.

For relighting, refer to lighting instructions.

Keep the burner and control compartment

clean by brushing and vacuuming at least

once a year. When cleaning the logs, use

a soft clean brush as the logs are fragile

and easily damaged.

2) Clean glass (never when unit is hot), ap-

pliance, louvers, and door with a damp

cloth. Never use an abrasive cleaner. The

gold louvers (and optional gold door) may

be scratched if abrasives are used to

clean them.

The heater is finished in a heat resistant

paint and should only be refinished with

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACEDONORNEARTHEAPPLI- ANCE.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIEDSERVICETECHNICIAN TOINSPECTTHEAPPLIANCEAND TO REPLACE ANY PART OF CON- TROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UN- DER WATER.

6) Verify proper operation after servicing.

GLASS

REPLACEMENT

Your Regency stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass, purchase your replacement from an authorized Regency dealer only, and follow the step-by-step instructions for replacement.

Never operate your unit with broken glass.

WARNING: Do not operate appliance with the glass front removed, cracked or bro- ken. Replacement of the glass should be done by a licensed or qualified service person.

heat resistant paint (not with wall paint).

Regency uses StoveBright Paint - Metallic

Black #6309.

3) Make a periodic check of burner for proper

position and condition. Visually check the

flame of the burner periodically, making

sure the flames are steady; not lifting or

floating. If there is a problem, call a qualified

service person.

4) The appliance and venting system must be

inspected before use, and at least annual-

ly, by a qualified field service person, to

ensure that the flow of combustion and

ventilation air is not obstructed.

During the annual service call, the burners

should be removed from the burner tray

and cleaned. Replace the embers - do not

block the pilot or burner ports.

5) Keep the area near the appliance clear and

free from combustible materials, gasoline

and other flammable

vapours and liquids.

WARNING: CHILDREN AND ADULTSSHOULDBEALERTEDTO THEHAZARDSOFHIGHSURFACE TEMPERATURE AND SHOULD

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under war- ranty.

DOOR AND GLASS

GASKET

If the door gasket requires replacement use 7/8" diameter oval door gasket (Part # 650- 920). The glass requires 5/8" flat glass gasket. See your Regency dealer.

MITREDDOOR

Removing Glass:

Note: Wearing gloves will protect your hands while handling glass.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the 24 nuts holding the glass re- tainers in place. Do not remove the nuts underneath the retainers.

STAYAWAYTOAVOIDBURNSOR CLOTHING IGNITION. YOUNG CHILDRENSHOULDBECAREFUL- LYSUPERVISEDWHENTHEYARE IN THE SAME ROOM AS THE AP- PLIANCE.

CAUTION: ANY SAFETY SCREEN ORGUARDREMOVEDFORSERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE.

GOLD-PLATED DOORS

The 24 carat gold plated finish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the finish and will void the warranty. Clean any fingerprints off before turning the unit on.

4)Remove the door catch plate.

5)Remove glass retainers on sides first (3

each side) then remove two center retain- ers.

Note: Center glass retainers are glued to center glass.

6)Remove glass from extrusions. When re- moving center glass, leave white insulation in place.

Regency U38 ULTIMATE Freestanding Gas Heater

17

Page 17
Image 17