Regency Wraps U38-NG Installation, Optional Outside Air, Clearances To Combustibles, Dimensions

Models: U38-LP U38-NG

1 24
Download 24 pages 42.42 Kb
Page 6
Image 6
U38-NG & U38-LP Clearances

INSTALLATION

9)Install Louvers, page 12.

U38-NG & U38-LP Clearances

10) Test for flue spillage (draft test), page 12.

 

 

11) Install optional Remote Control, or Wall Ther-

A Side Wall to Unit

7-1/2" / 190 mm

B Back Wall to Unit

6" / 155 mm

mostat, pages 12 and 13.

12) Final check, page 13.

E Side Wall to Unit

2" / 50 mm

 

 

Before leaving this unit with the customer, the

U38-NG&U38-LPREFERENCE

installer must ensure that the appliance is firing

DIMENSIONS

 

correctly and operation fully explained to cus-

 

 

tomer.

C Back Wall to Flue Centerline

10-3/4" / 273 mm

 

 

This includes:

D Side Wall to Flue Centerline

20-1/2" / 520 mm

F Side Wall to Flue Centerline

11" / 280 mm

 

OPTIONAL

OUTSIDE AIR

Outside air for combustion can be brought in either through the bottom of the pedestal or through the rear plate of the pedestal.

For both bottom and rear "outside air" the Ped- estal Cover Plate must be installed. Loosen the 4 screws on the rear of the pedestal and slide the cover plate over them. Slide the plate to the left to center it and tighten down the 4 screws.

Outside Air Through

1)Clocking the appliance to ensure the cor- rect firing rate (rate noted on label) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning or that results in damage is not the responsibility of the manu- facturer.

CLEARANCES TO COMBUSTIBLES

The clearances listed below are MINIMUM dis- tances. Measure the clearance to both the appliance and the chimney connector. (The farthest distance is correct if the two clearances do not coincide.) For example, if the appliance is set as indicated in one of the figures but the connector is too close, move the stove until the correct clearance to the connec- tor is obtained.

This unit can be installed on a solid combustible surface like a wood floor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit) is installed.

This appliance may be installed only with the clearances as shown in the situations pictured. Do not combine clearances from one type of installation with another in order to achieve closer clearances.

Use the minimum clearances shown in the diagrams below for installation with "B" vent.

Minimum ceiling height is 36" / 914 mm from top of unit.

Pedestal Bottom

Once you have properly marked the position of your unit as outlined in "General Information" and "Clearances to Combustibles", cut a prop- erly sized hole though the floor directly under your pedestal base to the outside. Pipe fresh air into the pedestal area by using appropriate metallic duct pipe with a mesh grill at the outside termination. Do not remove the knockout.

Rear View

Outside Air Through

Rear of Pedestal

Remove the blanking plate from the rear of the pedestal cover plate and bend the two tabs out 90 degrees. Pipe fresh air into the pedestal area by using duct pipe with a mesh grill at the outside termination. Attach the pipe to the tabs with screws.

Side View

If further reduced clearances are needed, ob- tain requirements for construction of a protect- ed wall from your local building authorities and their allowable reductions of the listed clear- ances.

6

Regency U38 ULTIMATE Freestanding Gas Stove

Page 6
Image 6
Regency Wraps Installation, Optional Outside Air, Clearances To Combustibles, U38-NG& U38-LPClearances, Dimensions