SMV80 Series IS. 325-1436.qxd 2/16/04 4:38 PM Page 3

Putting up your fixture Putting up your fixture

Step 1: TURN OFF THE POWER at the main fuse/breaker box.

Step 2: Install the bulb as described in “Installing the bulb.”

Step 3: Loosen, but do not remove, the two lens screws and retain ing clips on the front of the fixture.

Step 4: Insert the outer edge of the glass lens under the retaining clips. Make sure that you can read the caution printed on the front of the lens.

Step 5: Tighten the two lens screws, making sure that the retaining clips are tight enough to hold the lens in place.

Step 6: Loosen the swivel bolt (B) with adjustable wrench. Thread the coverplate onto the mounting arm of the fixture. Tighten the locknut to the coverplate (make sure the locknut is on the outside of the coverplate).

Step 7: Connect wires as described in “Wiring your fixture.”

Step 8: Install coverplate to junction box.

Step 9: Aim fixture vertically to desired position and tighten swivel bolt (B) using adjustable wrench. Do not aim fixture 60 degrees or more below horizontal.

Step 10: Apply weatherproof silicone caulking around coverplate to provide a watertight seal.

Step 11: Turn power back on.

Wiring your fixture Wiring your fixture

Step 1: TURN POWER OFF at main fuse/breaker box.

Step 2: Connect the black fixture wire to the black supply wire (hot).

Step 3: Connect the white fixture wire to the white supply wire (neutral).

Step 4: Connect the green ground wire to a suitable ground.

NOTE: Be careful to connect the wires correctly. Make sure no bare strands of wire extend from the wire nut or other approved wire connectors (not provided).

Installing the bulb

nstalling the bulb

Step 1: Screw the bulb securely into socket.

Step 2: Back the bulb out one or two turns, then screw bulb back in to ensure proper position in socket.

NOTE: When turned on, bulb will glow dimly at first, building to full power in 5-7 minutes. When replacing the bulb, you must always use the same wattage and type of bulb that was originally supplied with the fixture. Failure to do so could result in damage to the fixture and bulb. This will void the warranty. Always turn off or disconnect power before servicing to reduce risk of electrical shock.

3

Page 3
Image 3
Regent Sheffield SMV80 Putting up your fixture Putting up your fixture, Turn OFF the Power at the main fuse/breaker box