Reliance Water Heaters RUF 100 199 SERIES 101 RUF 100 199 ROUGH-IN-DIMENSIONS, Foreword, Approx

Models: RUF 100 199 SERIES 100 RUF 100 199 SERIES 101

1 36
Download 36 pages 16.01 Kb
Page 2
Image 2
RUF 100 199 ROUGH-IN-DIMENSIONS

RUF 100 199 ROUGH-IN-DIMENSIONS

GAS VALVE PIPING

RUF - 199

1/2" NPT

Table 1. RECOVERY CAPACITIES - NATURAL GAS / L.P.

 

 

 

Approx.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

Gas

Gallon

 

TEMPERATURE RISE - DEGREES °F - GALLONS PER HOUR

Model

BTU/Hr.

Usage

Capacity

30

 

40

50

60

70

80

90

100

110

120

130

140

RUF 199

199,900

nat/lp

100

767

 

575

460

384

329

288

256

230

209

192

177

164

 

 

 

Approx.

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas

Liter

 

 

TEMPERATURE RISE - DEGREES C - Liters PER HOUR

Model

kW-Hr

Usage

Capacity

 

 

 

 

 

 

 

 

 

 

 

 

17

22

28

33

39

44

50

56

61

67

72

78

RUF 199

58

nat/lp

379

2904

2178

1743

1452

1245

1089

968

871

792

726

670

622

Recovery capacities are based on 95% thermal efficiency.

FOREWORD

These designs comply with the current version of the American National Standard for Gas Water Heaters, Volume III, ANSI Z21.10.3 / CSA 4.3 as an automatic circulating tank water heater, and automatic storage water heaters.

Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and methods of piping necessary. It is highly essential that all water, gas piping and wiring be installed as shown on the diagrams.

Particular attention should be given to the installation of thermometers at the locations indicated on the diagrams as these are necessary for checking the proper functioning of the heater.

In addition to these instructions, the equipment shall be installed in accordance with those installation regulations in force in the local area where the installation is to be made. These shall be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made.

In the absence of local codes, the installation must comply with the current editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the National Electrical Code, NFPA 70. All documents are available from the Canadian Standards Association, 8501 East Pleasant Valley Road, Cleveland, OH 44131. NFPA documents are also available from the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.