5.12 Verify Check
(1) Choose [Verify Check(V)] from [Device(D)] menu or click [Verify Check] button to display the dialog
that shows execution process, and then perform verify check operation. After completing verify
check, the dialog is closed and "Verify Check…finish" dialog is displayed.
Note: When [Sum check (high speed)] is chosen from [Verify Process (V)] in [Others (O)]-[Setting(S)] dialog, the
data in the MCU is compared to the check sum value of the program data file. When [Read array (high
reliability)] is selected, the data in the MCU is compared to the program data file by the byte.
Figure 5.12.1 Verify Check
(2) Click [OK] in the "Verify Check…finish" dialog box to close the dialog.