6. Error Message List
Table 6.1.1 lists error messages, causes, and approaches provided from the M3S-UFLA32R.
Table 6.1.1 Error Message List
Error Message Cause Approach
1 MCU information is incorrect.
Please check whether the "UFLA32R.ini"
file is installed correctly.
There is no INI file. Reinstall the M3S-UFLA32R.
2 Can not open COM1. Can not open COM1. Check if the C OM1 is used in the
other application.
3 Motorola file is not specified.
Please specify Motorola file.
Motorola S format file is not
specified.
Specify the Motorola S format file.
4 The specified file is not a S-format file.
Please specify S-format file (*.mot).
The specified file is not Motorola
S-format file or there are some
contents errors.
Check the contents of the
selected file or specify different
file.
5 Address Error.
Start Address < NNNNNNNNh
The data record address of
chosen file is beyond the flash
memory.
Check the contents of Motorola S
format file or specify different file.
6 Address Error.
End Address > NNNNNNNNh
The record length of the chosen
file has an error.
Check the contents of Motorola S
format file or specify different file.
7 Receive timeout error. Timeout occurs during reception. Check the connection state of the
communication cable or restart
the M3S-UFLA32R, and then
reset the MCU.
8 Communication parameter error. Receive reply other than ACK
and NAK from the MCU.
Restart the M3S-UFLA32R and
reset the MCU.
9 Command execution error. Receive NAK from the MCU. Restart the M3S-UFLA32R and
reset the MCU.
10 Blank Check Error.
(Error Address: H'NNNNNN)
There is no blank after the
address H’NNNNNN.
-
11 Verify Check Error.
Error Address : H'NNNNNN
Error Data : H'AAAA (H'BBBB)
At the time of verify, the data of
the address H’NNNNNN are
H’AAAA (MCU side) and H’BBBB
(M3S-UFLA32R side) and not
corresponding.
Check if it is the same Motorola S
format file as the program in the
MCU.
12 Verify Check Error. Check sum value is not
corresponding at the time of
verification
Check if it is the same Motorola S
format file as the program in the
MCU.
13 ID verification error.
Please set up the ID code correctly.
The ID code in the MCU and the
one set in the M3S-UFLA32R
are different
Set the correct ID code to the
M3S-UFLA32R.
14 ID code is incorrect.
Please enter ID code with Hexadecimal.
Input ID code has an error. Enter ID code with Hexadecimal.
15 ID code is incorrect.
Please enter ID code correctly.
Input ID code has an error. Enter ID code with alphanumeric
characters.