16
Illegal Instructions
If illegal instructions are executed by STEP-type commands, the emulator cannot go to the next
program counter.
2.2 Specific Functions for the SH7630 E10A Emulator
The SH7630 E10A emulator does not support the following function:
MMU-related functions (The SH7630 does not mount the MMU.)
VPMAP-related command
Virtual and Physical specification in the [Configuration] window
Virtual and Physical specification on the command-line function
Virtual and Physical specification in the [Breakpoint] window
LDTLB instruction execution break function
MEMORYAREA_SET command
2.2.1 Emulator Driver Selection
Table 2.3 shows drivers which are selected in the [E10A Driver Details] dialog box.
Table 2.3 Type Number and Driver
Type Number Driver
HS7630KCM01H E10A PC Card Driver 7
HS7630KCM02H E10A PC Card Driver 8
HS7630KCI01H E10A PCI Card Driver 7
HS7630KCI02H E10A PCI Card Driver 8
2.2.2 Break Condition Functions
In addition to BREAKPOINT functions, the emulator has Break Condition functions. Three types
of conditions can be set under Break Condition 1, 2, 3. Table 2.4 lists these conditions of Break
Condition.