2.0INSTALLATION

2.1Selecting a Location for the StarInverter

In choosing a location for the StarInverter, consideration should be given to the following criteria:

The heat sink temperatures can exceed 158 degrees (70° C). The StarInverter must be installed so that the top of the unit will not come into contact with persons.

The StarInverter is suitable for installation both indoors and outdoors and the enclosure has been given a NEMA 3R rating.

When the StarInverter is installed outdoors, it should be shielded from rain and direct sunlight, if possible.

The StarInverter is designed to handle the temperature extremes of most climates. The operating and non-operating ambient temperature range is from -25°C to 40° C.

The following clearances are recommended for proper placement of the StarInverter:

A minimum 36clearance between the bottom of the inverter box and the ground.

A minimum 12clearance above the inverter box for ventilation.

A minimum 8” clearance around the side of the inverter box so that all Warning and Caution labels are clearly visible and able to be easily read.

Visibility of the operating LED’s and display located at the top front of the inverter box should also be considered.