2.3.a Grounding

A single point ground connection is located in the lower right hand side of the StarInverter cabinet. The PV panel grounding wire is terminated there. The AC ground connection is terminated next to the Line and Line 2/Neutral connections on the circuit board. The PV ground is bolted to the cabinet with a ¼-20 bolt. (Refer to Figure 7.)

Figure 6 includes schematic representations of the PVP1800, and PVP2800 single point grounding. The front cover is grounded through the two cover mounting screws.

PVP 1800

PV DC input

120-360 VDC

+

1A 15A

Control pcb

Power Distribution PCB

 

120 VAC 60Hz

-

20 A SB

L1

N

PV GND

Line Filter

GND

DC

Power

SupplyGND

System Block Diagram

Control pcb

Power Distribution PCB

 

Line Filter

15 A SB

L1

L2

PV GND

S

GND

DC

Power

Supply