Rheem 300 series Connections - Plumbing, Connection Sizes, Water Inlet And Outlet

Models: 300 series

1 32
Download 32 pages 18.97 Kb
Page 20
Image 20
CONNECTIONS – PLUMBING

CONNECTIONS – PLUMBING

CONNECTION SIZES

Hot water connection: RP¾/20.

Cold water connection: RP¾/20.

Relief valve connection: RP½/15.

Gas inlet: RP½/15.

All plumbing work must be carried out by a qualified person and in accordance with the National Plumbing Standard AS/NZS 3500.4 and local authority requirements.

All gas work must be carried out by a qualified person and in accordance with the Australian Gas Installations Standard AS 5601 and local authority requirements.

WATER INLET AND OUTLET

All pipe work must be cleared of foreign matter before connection and purged before attempting to operate the water heater. All olive compression fittings must use brass or copper olives. Use thread sealing tape or approved thread sealant on all fittings.

An isolation valve and non return valve must be installed on the cold water line to the water heater. Use the arrangement shown in the diagram. Refer also to “Hot Water Delivery” on page 15.

A disconnection union must always be provided at the cold water inlet and hot water outlet on the water heater to allow for disconnection of the water heater.

All water heaters have a plastic dip tube or fitting liner in the inlet and outlet fittings (see diagram). These must be in place for the water heater to function properly. Do not remove or damage them by using heat nearby. They will be pushed into the correct position as the fitting is screwed in.

20

Page 20
Image 20
Rheem 300 series installation instructions Connections - Plumbing, Connection Sizes, Water Inlet And Outlet