Rheem HE80-160LP, HE45-160LP, HE45-130N Ignition Lockout, ECO Switch Open, Possible Cause

Models: HE45-199LP HE80-130N HE45-130N HE119-160N HE80-130LP HE80-160N HE45-130LP HE45-100N HE45-100LP HE119-130LP HE45-160N HE45-199N HE119-199N HE80-160LP HE119-130N HE45-160LP HE119-160LP HE119-199LP HE80-199LP HE80-199N

1 30
Download 30 pages 54.5 Kb
Page 19
Image 19

LINE

K1

COMB BLOWER

K5

IGNITER ELEMENT

 

 

 

K3

K4

24

ECO/VENT

PRESSURE

GAS

GAS

VAC

SWITCH

SWITCH

VALVE

VALVE

 

 

 

RLY 1

RLY 2

 

 

 

 

GAS

 

 

 

 

VALVE

 

 

 

 

K1

 

 

CONTROL

 

K5

 

ELECTRONICS

K3

 

K4

 

 

 

 

 

CONTROL

WATER

 

 

 

HEALTH

TEMPERATURE

 

IGNITION LOCKOUT

Gas Valve LED Flashing

This condition results from a failure to establish burner ignition after three successive trials. In such cases:

First - Investigate the possible cause and remedy any observations.

Second - Momentarily press the red button on the display panel to reset the lockout condition.

Third - Confirm the proper appliance operation.

 

POSSIBLE CAUSE

 

REMEDY

1.

Burner ground wire broken

1.

Check wire and connection

 

or corroded.

 

at burner.

2.

Connectors unplugged.

2.

Check connectors.

3.

Flame probe faulty.

3.

Replace flame probe.

4.

Gas shut off.

4. Turn on gas supply

5.

Clogged gas valve.

5.

Replace gas valve.

6.

Faulty gas valve.

6.

Replace gas valve.

7.

Defective control.

7.

Replace control.

8.

Burner improperly adjusted.

8. Adjust burner.

9.

Dirty burner.

9.

Clean burner.

10. Improper line connection.

10. Verify green LED on the-

 

 

control board is illuminated

 

 

when power is applied.

11. Insufficient flame current.

11. Montior flame current.

 

 

See note below.

NOTE:

The flame current (flame rectification) is monitored by pressing the blue button to the left of the LEDs during the heat cycle or when the gas valve LED is illuminated. The 3-segment LED display will show the actual flame curent. The expected flame current draw is 4.0 to 5.1 micro-amps.

ECO SWITCH OPEN

ECO LED Flashing

 

 

 

 

K3

K4

LINE

24

ECO/VENT

PRESSURE

GAS

GAS

 

VAC

SWITCH

SWITCH

VALVE

VALVE

 

 

 

 

RLY 1

RLY 2

K1

 

 

 

 

GAS

 

 

 

 

 

 

 

 

 

 

VALVE

COMB

 

 

 

 

 

BLOWER

 

 

 

 

 

 

 

 

 

 

K1

K5

 

 

CONTROL

 

K5

 

 

 

 

IGNITER

 

ELECTRONICS

K3

 

K4

ELEMENT

 

 

 

 

 

 

 

 

 

 

 

CONTROL

WATER

 

 

 

 

HEALTH

TEMPERATURE

 

POSSIBLE CAUSE

1.Temperature probe is unplugged.

2.Temperature probe wiring damaged.

3.Water in tank is too hot. ECO is tripped.

4.Low water cutoff device is tripped.

REMEDY

1.Check connectors.

2.Repair wiring.

3.Normal condition when water temperature exceeds safety limit. Alow tank to cool or admit cold water into tank. Manually reset the control. Determine cause for overtemp condition.

4.Make sure tank is full of water.

19

Page 19
Image 19
Rheem HE80-160LP, HE45-160LP, HE45-130N, HE45-100LP, HE45-100N, HE45-130LP Ignition Lockout, ECO Switch Open, Possible Cause