Installation Check List

A.Outdoor Water Heater Location

Outdoor water heaters must be installed outdoors.

Protected from freezing temperatures.

B.Indoor Water Heater Location

Close to area of vent termination.

Indoors and protected from freezing temperatures.

C.Outdoor and Indoor Water Heater Location

Proper clearance from combustible surfaces observed.

Sufficient fresh air supply for proper operation of water heater.

Air supply free of corrosive elements and flammable vapors.

Provisions made to protect area from water damage.

Sufficient room to service heater.

Combustible materials, such as clothing, cleaning materials, rags, etc. clear of the heater and

vent piping.

Water heater is properly attached to the wall.

D.Water Supply

Water supply has sufficient pressure.

Air purged from water heater and piping.

Water connections tight and free of leaks.

Water filter is clean and in place.

Materials used are as instructed in this manual.

Water pipes are insulated and protected from freezing.

E.Gas Supply

Gas type matches rating plate.

Gas supply pressure is sufficient for the water heater.

Gas line equipped with shut-off valve, union and sediment trap.

Approved pipe joint compound used.

Soap and water solution used to check all connections and fittings for possible gas leak.

Gas Company inspected installation (if required).

F.Relief Valve

Pressure Relief Valve properly installed and discharge line run to open drain.

Discharge line protected from freezing.

G.Venting (Indoor Water Heaters Only)

Vent pipe material should be category III and meet UL1738 in US and ULC S636 in Canada.

Vent connector(s) pitched (1/4” per foot of length minimum) DOWNWARD or UPWARD to termination. If UPWARD, a condensate trap must be installed close to the heater. See page 14.

Vent connector(s) securely fastened together with high temperature silicone (500°F [260°C]) and air-tight.

All vent runs are properly supported.

Vent terminal is properly installed.

Sufficient combustion air is available.

Maximum and minimum vent lengths are observed.

H.Electrical Wiring

Voltage matches rating plate.

Water heater is properly grounded.

Supply cord and/or wiring meets all local codes.

25