Command No.

 

 

 

 

 

 

 

 

 

 

 

Command Description

 

 

 

 

[Active time (us) for the strobe signal]

 

 

 

 

 

 

 

90H:

 

Initial data: STROBEON _I[23..0] =10, STROBEDELAY _F[7..0] = 0, data range: 0 to 2,000,000

STROBEON_I[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91H:

 

Active time for the strobe signal = (STROBEON _I[23..0]). (STROBEON _F[7..0]) useconds

STROBEON_I[15..8]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

92H:

Active time for the strobe signal is set as below.

 

 

 

 

 

STROBEON_I[23..16]

 

0: No strobe signal output

 

 

 

 

 

 

 

 

 

 

93H:

 

1 to 9: 10 us

 

 

 

 

 

 

 

 

 

 

 

 

STROBEON_F[7..0]

 

Greater than 9: set value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Output signal selection for the power-I/O connector] Initial data: OUTSEL[7..0] = 20H

F0H:

 

Sets the output signal from the power/IO connector.

 

 

 

OUTSEL

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

D6

D5

 

D4

 

D3

 

D2

D1

 

D0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7 to D4:

Output signal for 3pin of the power/IO connector

 

 

 

 

 

 

 

 

 

 

 

 

 

0: FrameTriggerWait signal

1: UserOutput signal

 

 

 

 

 

 

 

 

 

 

2: ExposureActive signal

3: TriggerAuxiliary signal

 

 

 

 

 

 

 

 

 

 

4: TriggerInternal signal (after mask and delay process)

 

 

 

 

 

 

 

 

 

 

5: SensorReadOut signal

 

 

 

 

 

 

 

 

 

 

 

 

 

6 to F: No Function (Prohibited setting. Do not set these values)

 

 

D3 to D0:

Output signal for 2pin of the power/IO connector

 

 

 

 

 

 

 

 

 

 

 

 

 

0: FrameTriggerWait signal

1: UserOutput signal

 

 

 

 

 

 

 

 

 

 

2: ExposureActive signal

3: TriggerAuxiliary signal

 

 

 

 

 

 

 

 

 

 

4: TriggerInternal signal (after mask and delay process)

 

 

 

 

 

 

 

 

 

 

5: SensorReadOut signal

 

 

 

 

 

 

 

 

 

 

 

 

 

6 to F: No Function (Prohibited setting. Do not set these values)

 

 

Note: When “UserOutput signal” is selected, set the status of the signal with “UserOutput signal for the

 

 

 

power/IO

connector (TEST2-D3,4)”.

 

 

 

 

 

 

 

 

 

 

 

[UserOutput signal for the power-I/O connector] Initial data: TEST2[7..0] = 00H

 

F1H: TEST2[7..0]

 

Sets the status of the UserOutput signal.

 

 

 

 

 

 

 

 

 

D[7..0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D7

 

D6

D5

 

D4

 

D3

 

D2

D1

 

D0

 

 

 

 

 

 

D7 to D5:

No function

 

 

 

 

 

 

 

 

Always set as “000”

 

 

D4:

 

UserOutput signal for 3pin of the power/IO connector

0: Low

1: High

 

 

D3:

 

UswerOuput signal for 2pin of the power/IO connector

0: Low

1: High

 

 

D2 to D0:

No function

 

 

 

 

 

 

 

 

Always set as “000”

 

 

Note: The UserOutput signal is enabled whenever “UserOutput signal” is selected at the “Output signal

 

 

selection (OUTSEL)”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 