RIDGID microEXPLORER manual Tool Inspection, Tool and Work Area Set-Up

Models: microEXPLORER

1 71
Download 71 pages 22.68 Kb
Page 9
Image 9

microEXPLORERDigital Inspection Camera

Port Cover

ON\OFF

Button

Figure 8 – ON/OFF Button

7.Check that the warning label is present, firmly attached and readable. Do not op- erate the microExplorer Digital inspec- tion camera without the warning label.

Figure 9 – Warning Label

Tool Inspection

WARNING

Daily before use, inspect your inspec- tion camera and correct any problems to reduce the risk of serious injury from electric shock and other causes and prevent tool damage.

8.Check to make sure the expansion bay door is fully closed.

9.With dry hands re-install the battery mak- ing sure to properly close the battery door.

10.Turn the power on (Figure 8) and make sure the device cycles through the splash screen and then displays the live screen. Consult the troubleshooting section of this manual if problems arise.

11.Turn camera OFF.

1.Make sure the unit is OFF.

2.Remove the battery and inspect it for signs of damage. Do not use the microEXPLORER inspection camera if the battery is damaged in any way.

3.Clean any oil, grease or dirt from the equipment, especially the handles and controls. This helps prevent the tool from slipping from your grip.

4.Inspect the camera head lens for conden- sation. To avoid damaging the unit, do not use the camera if condensation forms inside the lens. Let the water evaporate before using again.

5.Inspect the full length of the cable for cracks or damage. A damaged cable could allow water to enter the unit and in- crease the risk of electrical shock.

6.Check to make sure the connections be- tween the handheld unit and imager cable are tight. All connections must be properly assembled for the cable to be water resistant. Confirm unit is properly assembled.

Tool and Work Area Set-Up

WARNING

Set up the microEXPLORER inspection camera and work area according to these procedures to reduce the risk of in- jury from electrical shock, entanglement, and other causes and prevent tool and system damage.

1.Check work area for:

Adequate lighting.

Flammable liquids, vapors or dust that may ignite. If present, do not work in area until sources have been identified and corrected. The microEXPLORER inspection camera is not explosion proof and can cause sparks.

Ridge Tool Company

7

Page 9
Image 9
RIDGID microEXPLORER manual Tool Inspection, Tool and Work Area Set-Up, Check work area for Adequate lighting