Rinnai Q130SN, Q175CP, Q85SN Error, maintenance and warranty, i NOTICE i NOTICE i NOTICE i NOTICE

Models: Q205SN Q130SP Q175CN Q205SP Q175SP Q130SN Q175SN Q85SP Q85SN Q175CP

1 32
Download 32 pages 29.74 Kb
Page 14
Image 14
Error, maintenance and warranty

Error, maintenance and warranty

i NOTICE

i NOTICE

i NOTICE

i NOTICE

9

-Series

10

Q

Rinnaiinstructions

8

 

Operating

7

 

If a fault is detected the boiler will be blocked. This will be reflected, by an alternate display of

Good, with an E of Error or a BL of Blocking and a number code.

You can try to reset the boiler by pressing the Reset key once. If the problem remains please contact your installer and inform them about the fault and give them the number code.

If you discover any leaks from the boiler contact your installer.

We advise you to obtain a service contract with your installer for regular maintance and adjustment to keep your boiler safe and in good condition.

The casing of the boiler consists of metal and plastic parts which can be cleaned with a normal non abrasive cleaning agent.

Periodic cleaning of the condensate collection and disposal system must be carried out.

Before putting the boiler into operation after periodic cleaning fill the condensate trap with 1.27 cups / 300 ml of water.

Step 1: Condensate trap

-First remove the condensation cup (7); Check this for impurities. If there are no impurities it is not necessary to clean the condensate cup

-Grease the O-rings again with acid free O-ring grease to make fitting easier;

-If there is a leak at the condensation cup (7) or tray (9) the complete condensate trap unit (10) has to be replaced by S4451610;

Step 2: Refitting is done in reverse order.

Note that all gaskets seal completely.

14

Page 14
Image 14
Rinnai Q130SN, Q175CP, Q85SN, Q85SP, Q175SN, Q175SP manual Error, maintenance and warranty, i NOTICE i NOTICE i NOTICE i NOTICE