7
Safety Devices
Noise Level Range HI LOW 47 37dB(A)
TYPE
SPECIFICATIONS FOR VENT SIZES
S Thin Walls Mobile Home
Wood Walls
Wood/Brick
Brick/Block
Special
3"4 1/2"
(75 115)mm
4 1/2"9 1/2"
(115 240 )mm
9 1/2"15 3/4"
(240 400 )mm
15 3/4"23 5/8"
(400 600 )mm
23 5/8"31 1/2"
(600 800 )mm
A
B
C
D
3 1/8" (80mm)
13ft., 2 bends (4m, 2 bends)
Combustion Method
Air Supply Exhaust
Radiation Method
Forced combustion
Closed Type
Forced convection
Wall Penetration
Hole
Max. Extended
AIR SUPPLY/
EXHAUST PIPE
Flame failure Flame rod
Over heat Bi-metal switch, thermal fuse, thermistor
Power failure PCB
Power surge 5 Amp. fuse
Fan delay Micro computer timer
Pre-purge Combustion fan, pre-purge timer, spark sensor
Room over heat Automatic cut off at 104°F after 10 minutes
** BTU - Efficiency increase with vent size. Clearances from combustibles see page 3.
** Thermal efficiency rating determined under continuous operating conditions, and was determined
independently of any installed system.