Rinnai V53E Clearances from Appliance, Attachment of the Water Heater, V53iV53e, to Combustibles

Models: V53I V53E

1 64
Download 64 pages 47.47 Kb
Page 18
Image 18
Clearances from Appliance

Clearances from Appliance

V53iV53e

 

to Combustibles

to Non- Combustibles

 

 

 

Top of

6 inches *

2 inches *

Heater

(152 mm)

(51 mm)

Back of

0 (zero)

0 (zero)

Heater

 

 

 

 

 

Front of

6 inches

6 inches

Heater

(152 mm)

(152 mm)

Sides of

2 inches

1/2 inch

Heater

(51 mm)

(13 mm)

Ground/

12 inches

12 inches

Bottom

(305 mm)

(305 mm)

 

 

 

Vent

0 (zero)

0 (zero)

 

 

 

 

 

to Combustibles

to Non- Combustibles

 

 

 

Top of

12 inches

2 inches

Heater

(305 mm)

(51 mm)

Back of

0 (zero)

0 (zero)

Heater

 

 

Front

24 inches

0 (zero)

(Panel)

(610 mm)

 

Front

24 inches

24 inches

(Exhaust)

(610 mm)

(610 mm)

Sides of

6 inches

1/8 inch

Heater

(152 mm)

(3.2 mm)

Floor/

12 inches

2 inches

Ground

(305 mm)

(51 mm)

to top

to side

to front

to ground/bottom

* 0 inches from vent components and condensate drain line.

The clearance for servicing is 24 inches in front of the water heater.

For closet installation: clearance is 6 inches (152 mm) from the front.

Attachment of the Water Heater

1.Identify the installation location and confirm that the installation will meet all required clearances.

2.Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section.

NOTE: Rinnai water heaters should be installed in an upright position. Do not install upside down or on it side.

wall installation

brackets

18

V53i & V53e Operation and Installation Manual

Page 18
Image 18
Rinnai V53E Clearances from Appliance, Attachment of the Water Heater, V53iV53e, to Combustibles, to Non- Combustibles