ritetemp 401-014 manual 8022C Features, Return To Page

Models: 401-014

1 9
Download 9 pages 41.98 Kb
Page 9
Image 9
8022C Features
Single Stage HEAT PUMP
R O or B
Change Over
SINGLE STAGE HEAT PUMP

From Furnace

 

G

STEP 1 - Connect the G wire to the G

 

and

AC unit

 

terminal on the thermostat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

This connects the Fan.

jumper

 

 

O

wire

 

 

 

STEP 2 - Add a jumper wire

 

 

 

 

 

 

or

 

 

 

 

B

 

between W and Y.

 

 

 

 

 

 

 

R

 

 

STEP 3 - Connect the Y wire to the

O or B

C

 

 

Y terminal on the thermostat.

 

 

 

 

 

 

 

 

This connects the Compressor.

STEP 4 - Connect the O or B wire to the O or B terminal

C

24VAC

on the thermostat. (If you have both O and B contact

Power

Ritetemp or your local HVAC contractor for further help)

 

This connects the change over valve.

 

STEP 5 - Connect the R wire to the RC terminal on the Thermostat. This connects to the 24vac power.

Your HVAC system is now connected to the thermostat.

Thermostat

Manual backgroundManual background A

jumper wire

Y G

Comp FAN

Return To Page 7

PG 15

NOTE: Wires marked with the dotted line are optional.

8022C Features

The 8022C can be used with most 24 volt gas, oil or electric heating and air conditioning systems, single- stage heat pumps or gas millivolt heating systems. It cannot be used with 120 volt heating systems or multistage heat pumps. Ask The Home Depot for other thermostats to control those systems.

The 8022C is programmable. There are four programming periods per day. Each period can be programmed separately.

You can use the built-in time/temperature programs, or alter them to suit your schedule.

The 8022C separately programs 7 days a Week and a Spacial

Day - for both heating and cooling.

OFF

HEAT

COOL

FAN

ON

AUTO

You can easily override the programmed temperatures for as little as one programming period or for an entire vacation.

A large liquid crystal display shows time, day of the week, room and set temperatures. It will also remind you when the filter

 

should be changed in your blower.

 

Temperature swing adjustment lets you fine-tune your system for maximum comfort and energy

 

efficiency.

 

A 4-minute minimum off time in COOL protects your air conditioning system from being damaged.

PG 16

Two "AA" batteries (not included) are used to retain your time and temperature programs, and to

run the thermostat.

 