HVAC SYSTEM

From

Furnace

and

AC unit

 

 

Y

RH or R

Manual background STEP 1 - Connect the Y wire to the Y terminal on the thermostat. This connects to the Cooler compressor.

4 WIRE

Thermostat

Manual backgroundManual backgroundManual background A

jumper wire

CG

Manual background W

thermostat. This connects

STEP 2 - Connect the RH or R wire to the RH terminal on the

the Heater/Cooler Power.

C RH

W

Y

G

Heat

Heat

Cool

FAN

Power

Comp

 

 

HVAC SYSTEM

STEP 3 - Connect the W wire to the W terminal on the thermostat. This connects to the heater control line.

STEP 4 - Connect the G wire to the G terminal on the Thermostat. ￿

This connects to the Fan.

Return To Page 9

NOTE: Wires marked with the dotted line are optional.

PG 13

5 WIRE

From

Furnace

and

AC unit

Y

STEP 1 - Remove the red

Thermostat

Jumper wire.

A

 

 

RH

STEP 2 - Connect the Y

 

 

 

 

 

RC

wire to the Y terminal on

 

Remove

 

 

 

 

jumper

C

 

G

the thermostat. This connects

 

wire

W

 

 

 

 

to the Cooler compressor.

 

RC

RH

 

 

 

 

 

STEP 3 - Connect the RH wire to the

 

COOL

 

RH terminal on the thermostat. This connects to

C

Power

 

HEAT

 

the Heater Power .

 

 

 

 

 

Power

 

STEP 4 - Connect the RC wire to the RC terminal

on the thermostat. This connects to the Cooling Power .

STEP 5 - Connect the W wire to the W terminal on the thermostat. This connects to the heater control line.

STEP 6 - Connect the G wire to the G terminal on the Thermostat. This connects to the Fan.

Your HVAC system is now connected to the thermostat.

W Y G

Cool

HeatFAN

Comp

PG 14

NOTE: Wires marked with the dotted line are optional.

 