Before you Connect Wires

9 Wire Connections

PG 7

 

Make sure your wires are labeled. This is necessary to determine which step-by-step wiring diagram you should use. This may require you to find the 'other end' connection for each wire on your heating or air conditioning equipment and read the label there.

If you have a Zoned Heating/Cooling system with multiple thermostats, please refer to our website at www.ritetemp-thermostats.com for installation notes or call 1-888-515-2585.

Before you Connect Wires

Please refer back to these guidelines for safe and secure wire connections.

.Take care not to damage the labels for each wire in handling.

.Strip insulation 3/8 in. (9.5mm) from wire ends.

.Connect labeled wires only to a terminal with corresponding letter.

.Bend the wire slightly, insert the wire under the contact plate and tighten the screw down onto the wire.

What Wires Do You Have?

The Wire chart shows wire labels used on Ritetemp thermostats. Please determine what wires you have and select the correct wiring diagram to "go to" on pages 9.

Caution

Do not allow

 

wires to touch

each other or parts on unit . Wires must be routed through the hole in the back plate, below the terminal block, or they will hit parts on the cover.

The Wire Chart below will help you determine the terminal connections you will use on your new thermostat. See chart section that applies to your heat/cool system.

ONE

Power

Wire

TWO

Power

Wires

Control wires

 

HEAT

PUMPS

 

ZONED

MOTOR

VALVES

ZONED

SOLENOID

VALVES

OLD THERMOSTAT

NEW THERMOSTAT

DESCRIPTION

R or RH or 4 or V

RH or RC(leave jumper)

Power Wire

 

 

 

RH or 4 or V

RH (remove jumper)

Power Heat

RC or R

RC (remove jumper)

Power cool

W or H

W

Heat return

Y or M

Y

Cool return (compressor)

G or F

G

Fan return

C or X

C

AC source for thermostat

W2 or H2

W2

2nd stage of heat

Y2

do not connect

2nd stage of cool (n/a)

W2

W2

Heat pump Aux heat

E

 

Do not connect

O (see note below)

O

Dmpr/Chg-over (pwr in cool)

B (see note below)

B

Dmpr/Chg-over (pwr in heat)

 

 

 

5 or R

RH

Power wire (pwr)

4 or W

W

Turn Valve on

6 or Y or B

A

Turn Valve off

 

 

 

R

RH

Power wire (pwr)

Y or B

W

Turn Valve off

W

A

Turn Valve on

 

 

 

Note: On a heat pump, if O and B are both present, connect O to O and tape off B.

For wiring support call 1-888-515-2585 or visit our website at www.ritetemp-thermostats.com PG 8