Roberts Gorden 125, 75, 100, 45, 30, 60 service manual Ignition Electrode and Flame Probe

Models: 60 30 45 125 100 75

1 62
Download 62 pages 55.65 Kb
Page 50
Image 50
14.3 Ignition Electrode and Flame Probe

UHA LOW PROFILE UNIT HEATER INSTALLATION OPERATION AND SERVICE MANUAL

14.3 Ignition Electrode and Flame Probe

 

 

Inshot

 

 

Burners

Manual Reset

 

 

Limit Switch

 

 

(Position may vary.)

 

 

 

 

Flame

 

Flame

Probe

 

 

 

Probe

 

Limit

 

 

Switch

 

 

 

 

Burner Compartment

Ignition

 

Front Views

Electrode

 

 

 

 

Ignition

 

 

Electrode

.120 (3 mm) spark

gap

Inshot

Burners

To replace the electrode or flame probe, remove the electrical lead and screw.

Pull out from mounting. Refit in reverse ensuring that the gap to burner is as shown in the front view of the burner compartment.

Description

Part Number

Qty

Spark Electrode

90427411

1

Automatic Ignition Flame Probe

90439300

1

Transformer

90436900K

1

Ignition Module

90434008

1

Inshot Burners UHA[X][S] 30

92000002

2

Inshot Burners UHA[X][S]45

92000002

3

Inshot Burners UHA[X][S] 60

92000002

4

Inshot Burners UHA[X][S] 75

92000002

5

Inshot Burners UHA[X][S] 100

92000002

6

Inshot Burners UHA[X][S] 125

92000002

7

Limit Switch

90412104

1

Manual Reset Limit Switch

90412106

1

44

Page 50
Image 50
Roberts Gorden 125, 75, 100, 45, 30, 60 service manual Ignition Electrode and Flame Probe